翻修全髋关节置换术中使用的约束性髋臼组件:一项登记分析
该研究基于澳大利亚骨科协会国家关节置换登记系统(AOANJRR),比较翻修全髋关节置换术(THA)中约束性与标准非约束性髋臼组件的翻修率。共纳入9509例首次翻修THA,其中700例使用约束性组件。当纳入大直径金属对金属组件时,约束性组件3个月后翻修率显著更高(HR=1.37;P=.005);排除后两组无差异。因脱位行首次翻修者,约束性组件9个月后因再脱位翻修率更高。
要点
- 纳入9509例首次翻修THA,700例使用约束性组件。
- 含大直径金属对金属组件时,约束性组件3个月后翻修率显著更高(HR=1.37;P=.005)。
- 排除大直径金属对金属组件后,两组翻修率无差异。
核心结论
- 约束性髋臼组件与标准非约束性组件的二次翻修率相似,无论首次翻修原因为何或用于治疗脱位。
- 尽管约束性组件可能用于更困难的不稳定髋关节,但其因再脱位导致的二次翻修率更高。
研究设计与样本
- 基于澳大利亚骨科协会国家关节置换登记系统(AOANJRR)的登记分析,纳入有记录的原发手术且初始诊断为骨关节炎的翻修THA,比较约束性与标准非约束性组件。
- 采用Kaplan-Meier法估计生存率,并使用Cox比例风险模型计算风险比进行组间比较。
主要发现
- 共纳入9509例THA首次翻修手术,其中700例使用约束性组件。
- 当纳入大直径金属对金属组件时,约束性组件3个月后翻修率显著更高(HR=1.37;P=.005)。
- 排除大直径金属对金属组件后,两组二次翻修率无差异。
- 当分析限于因脱位行首次翻修时,约束性组件9个月后因再脱位导致的二次翻修率更高。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Constrained acetabular components have a mechanism to lock in the femoral head. They have been developed to control postoperative dislocation, particularly in revision total hip arthroplasty (THA). Although these components may reduce dislocation, there are durability concerns: with reports of locking mechanism failures and loosening. We wanted to determine the outcome of constrained components in controlling dislocation, and if these components had a higher rate of second revision when compared with standard nonconstrained components. METHODS: Revision THA procedures from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) with a recorded primary procedure and initial diagnosis of osteoarthritis were used to compare constrained and standard nonconstrained components. Kaplan-Meier estimates of survivorship were calculated, and hazard ratios using Cox proportional hazard models were used to compare groups. RESULTS: There were 9509 THA first-revision procedures and 700 constrained components. Constrained components had a significantly higher revision rate after 3 months when large-head metal-on-metal components were included (hazard ratio = 1.37; P = .005). When large-head metal-on-metal components were excluded, there was no difference in the rate of second revision between the 2 groups. When the analysis was limited to first revision for dislocation, constrained components had a higher second revision rate for further dislocation after 9 months. CONCLUSION: Constrained acetabular components had similar second-revision rates when compared with standard nonconstrained components, both for all first-revision reasons and when used to treat dislocation. Although possibly used for the more difficult unstable hips, constrained components had a higher rate of second revision for further dislocation.
引用
- Lewis PL, Graves SE, de Steiger RN, et al. Constrained Acetabular Components Used in Revision Total Hip Arthroplasty: A Registry Analysis. J Arthroplasty. 2017. PMID: 28576624. doi:10.1016/j.arth.2017.04.043
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。