文献速递关节外科创伤骨科

全膝关节置换术后伸膝装置断裂的重建

Reconstruction of Disrupted Extensor Mechanism After Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-05-11

本研究回顾性分析学术三级中心16例全膝关节置换术后伸膝装置断裂行同种异体移植重建的患者,平均随访3.3±2.2年。结果显示膝关节协会评分(KSS)疼痛与功能评分及伸膝迟滞均显著改善,但31%病例出现伸膝迟滞>30°或需再次手术。

要点

  • 同种异体移植重建伸膝装置后KSS疼痛评分从术前40±14分改善至末次随访67±15分(P<.001)。
  • 伸膝迟滞从术前35°±16°降至末次随访14°±18°(P<.001),平均髌骨上移8±10 mm。
  • 31%病例出现伸膝迟滞>30°或需再次伸膝装置重建、感染或关节融合手术。

核心结论

  • 作者10年同种异体移植重建伸膝装置的经验显示结果合理,但约三分之一患者预计会出现失败。

研究设计与样本

  • 回顾性识别学术三级中心连续的全膝关节置换术后伸膝装置断裂行同种异体移植重建的患者。
  • 纳入16例患者,重建时平均年龄61±14岁,至少随访2年,平均随访3.3±2.2年。

主要发现

  • KSS疼痛评分从术前40±14分改善至末次随访67±15分(P<.001)。
  • KSS功能评分从术前26±21分改善至末次随访48±25分(P<.001)。
  • 伸膝迟滞从术前35°±16°降至末次随访14°±18°(P<.001)。
  • 平均髌骨上移8±10 mm。
  • 5例(31%)出现伸膝迟滞>30°或需再次伸膝装置重建、感染或关节融合手术。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a debilitating complication that results in extension lag, limited range of motion, difficulty in walking, frequent falls, and chronic pain. This study presents the clinical and radiographic results of reconstruction after extensor mechanism disruption in TKA patients. METHODS: Consecutive patients with allograft reconstruction of extensor mechanism after TKA were identified retrospectively from an academic tertiary center for revision TKA. RESULTS: Sixteen patients with a mean age of 61 ± 14 years at extensor mechanism reconstruction with a minimum of 2-year follow-up were included. The mean follow-up was 3.3 ± 2.2 years. Knee Society score (KSS), before and at final follow-up extension lag, range of motion, and radiographic change in patellar height were reviewed. There were statistically significant improvements between preoperative and final follow-up KSS (P < .001; KSS for pain, preoperative 40 ± 14 points to final follow-up 67 ± 15 points [P < .001]; KSS for function, preoperative 26 ± 21 points to final follow-up 48 ± 25 points [P < .001]). The extension lag was also reduced from 35° ± 16° preoperatively to 14° ± 18° (P < .001) at final follow-up. There was an average proximal patellar migration of 8 ± 10 mm. Five (31%) cases had an extensor lag of >30° or revision surgery for repeat extensor mechanism reconstruction, infection, or arthrodesis. CONCLUSION: Our 10-year experience using allografts during extensor mechanism reconstruction demonstrates reasonable outcomes, but failures are to be anticipated in approximately one-third of patients.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Lim CT, Amanatullah DF, Huddleston JI, et al. Reconstruction of Disrupted Extensor Mechanism After Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28634096. doi:10.1016/j.arth.2017.05.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。