文献速递脊柱外科小儿骨科

胸腔镜前路脊柱融合术后肺体积变化:三维计算机断层扫描研究

Change in Lung Volume Following Thoracoscopic Anterior Spinal Fusion Surgery: A 3-Dimensional Computed Tomography Investigation.
PubMed 文献 · Spine (Phila Pa 1976) · 2017-01-01

本研究从伦理批准的历史数据库中选择23例女性青少年特发性脊柱侧凸患者,比较胸腔镜前路脊柱融合术前与术后2年低剂量CT扫描的三维肺体积。术后左肺体积、总肺体积及半胸比均显著增加,右左肺体积比无显著变化(P=0.36)。肺体积变化与Cobb角减小、身高增加及半胸对称性改善显著正相关,但术后肺体积仍低于无胸廓畸形女性的第50百分位。

要点

  • 胸腔镜前路脊柱融合术后2年左肺体积、总肺体积及半胸比显著增加。
  • 右左肺体积比术后无显著变化(P=0.36)。
  • 肺体积变化与Cobb角减小、身高增加及半胸对称性改善显著正相关。

核心结论

  • 胸腔镜前路脊柱融合术使术后肺体积出现统计学显著增加,并改善胸廓结构的对称性。
  • 术后肺体积仍处于无胸廓畸形女性第50百分位以下。
  • 肺体积变化与Cobb角变化、半胸不对称性变化及患者身高增加显著相关,这些是胸廓畸形矫正手术的重要结果。

研究设计与样本

  • 从伦理批准的历史数据库中选取23例女性青少年特发性脊柱侧凸患者,均有术前及术后2年低剂量CT扫描。
  • 重建三维肺体积以确定解剖肺体积,获取右肺体积、左肺体积、总肺体积、右左肺体积比及半胸对称性。
  • 采用Cobb角、肋峰、融合节段及患者身高与肺体积结果进行相关性分析。
  • 证据等级为3级。

主要发现

  • 术后2年左肺体积、总肺体积及半胸比均显著增加。
  • 右左肺体积比术后2年无显著变化(P=0.36)。
  • 统计回归发现肺体积变化与Cobb角减小、身高增加及半胸对称性比率改善呈显著正相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Lung volumes and thoracic anatomy were measured from low-dose computed tomography (CT) scans preoperatively and 2 years following thoracoscopic anterior spinal fusion (TASF) for adolescent idiopathic scoliosis (AIS). OBJECTIVE: The aim of this study was to assess changes in lung volume after TASF surgical correction. SUMMARY OF BACKGROUND DATA: AIS patients are known to have decreased pulmonary function as a consequence of their spinal and ribcage deformity. Several studies have evaluated changes in pulmonary function clinically after scoliosis correction surgery showing varied results. To date, there have been no published studies using CT to evaluate lung volume changes following TASF. METHODS: Twenty-three female AIS patients with both pre- and 2 years postoperative low-dose CT scans were selected from an ethically approved, historical databank. Three-dimensional lung volumes were reconstructed to determine anatomical lung volumes. Right and left lung volumes, total lung volume, and right-to-left lung volume ratio were obtained as well as hemithoracic symmetry, to indicate the extent of thorax deformity. Cobb angle, rib hump, levels fused in surgery, and patient height were used for correlation analysis with the lung volume results. RESULTS: Left lung volume, total lung volume, and hemithoracic ratio all increased significantly 2 years after surgery. There was no significant change in right-to-left lung volume ratio (P = 0.36). Statistical regression found significant positive correlation between lung volume changes, reduction in Cobb angle, increase in height, and improvement in hemithoracic symmetry ratio. CONCLUSION: TASF resulted in a statistically significant increase in lung volume following surgery, as well as improvement in the symmetry of the thoracic architecture; however, the postoperative lung volumes remained in the lower 50th percentile relative to females without thoracic deformity. Furthermore, change in lung volume was significantly correlated with changes in Cobb angle, hemithoracic asymmetry, and increased patient height, which are important consequences of thoracic deformity correction surgery. LEVEL OF EVIDENCE: 3.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Yu CG, Grant CA, Izatt MT, et al. Change in Lung Volume Following Thoracoscopic Anterior Spinal Fusion Surgery: A 3-Dimensional Computed Tomography Investigation. Spine (Phila Pa 1976). 2017. PMID: 28609321. doi:10.1097/BRS.0000000000001949

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。