肩袖修复术后10年冈上肌质子密度脂肪分数与等长肌力相关:肩关节定量磁共振成像研究
横断面研究纳入13例单侧自体骨膜瓣加强肩袖修复术后10.9±0.4年患者,双侧肩关节MRI共26肩,评估肩袖肌质子密度脂肪分数(PDFF)与Goutallier评分、软骨T2弛豫时间及临床等长肌力的关系。冈上肌PDFF与Goutallier评分正相关(R=0.75,P<.001),与等长肌力负相关(R=-0.49,P=.011),校正肌肉面积和肌腱断裂后仍显著(R=-0.41,P=.048)。作者认为PDFF可提供独立的临床相关信息。
要点
- 肩袖修复术后10年,同侧肩PDFF均值14.2%±8.5%,对侧9.2%±7.8%(P=.002)。
- 冈上肌PDFF越高,Goutallier评分越高(R=0.75,P<.001),等长肌力越低(R=-0.49,P=.011)。
- 校正肌肉面积和肌腱断裂后,冈上肌PDFF与等长肌力仍负相关(R=-0.41,P=.048)。
核心结论
- MRI衍生的肩袖肌PDFF与等长肌力相关,且独立于肌肉萎缩和肌腱断裂。
- PDFF可在定量层面提供追踪肩袖肌肉组成的补充性临床相关信息。
研究设计与样本
- 横断面研究,证据等级3。
- 13例单侧自体骨膜瓣加强肩袖修复术后10.9±0.4年患者(11男2女,年龄72±8岁),双侧肩关节MRI共评估26肩。
主要发现
- 同侧肩全层再撕裂6例,对侧肩全层撕裂6例。
- 等长肩外展肌力同侧50±24 N vs 对侧54±24 N,差异无统计学显著(P=.159)。
- 肩袖肌PDFF均值11.7%±10.4%;同侧14.2%±8.5% vs 对侧9.2%±7.8%(P=.002)。
- 冈上肌PDFF与Goutallier评分正相关(R=0.75,P<.001),与等长肌力负相关(R=-0.49,P=.011);校正肌肉面积和肌腱断裂后仍负相关(R=-0.41,P=.048)。
- 肱骨软骨缺损越严重与冈上肌PDFF越高相关(R=0.44,P=.023);软骨T2值与肌肉PDFF无相关(P>.05)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Quantitative muscle fat-fraction magnetic resonance (MR) imaging techniques correlate with semiquantitative Goutallier scores with failure after rotator cuff (RC) repair. PURPOSE: To investigate the relationship of proton density fat fraction (PDFF) of the RC muscles with semiquantitative MR scores, cartilage T2 relaxation times, and clinical isometric strength measurements in patients 10 years after unilateral RC repair. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: Bilateral shoulder MR imaging was performed in 13 patients (11 male, 2 female; age, 72 ± 8 years) 10.9 ± 0.4 years after unilateral autologous periosteal flap augmented RC repair (total shoulders assessed, N = 26). Goutallier classification, muscle atrophy, RC tendon integrity, and cartilage defects were determined based on morphological MR sequences. A paracoronal 2D multi-slice multi-echo sequence was used for quantitative cartilage T2 mapping. A chemical shift-encoding-based water-fat separation technique (based on a 6-echo 3D spoiled gradient echo sequence) was used for quantification of the PDFF of RC muscles. Isometric shoulder abduction strength was measured clinically. Mean and SD, Pearson correlation, and partial Spearman correlation were calculated. RESULTS: There were 6 RC full-thickness retears in ipsilateral shoulders and 6 RC full-thickness tears in contralateral shoulders. Isometric shoulder abduction strength was not significantly different between ipsilateral and contralateral shoulders (50 ± 24 N vs 54 ± 24 N; P = .159). The mean PDFF of RC muscles was 11.7% ± 10.4% (ipsilateral, 14.2% ± 8.5%; contralateral, 9.2% ± 7.8%; P = .002). High supraspinatus PDFF correlated significantly with higher Goutallier scores ( R = 0.75, P < .001) and with lower isometric muscle strength ( R = -0.49, P = .011). This correlation remained significant after adjustment for muscle area measurements and tendon rupture ( R = -0.41, P = .048). More severe cartilage defects at the humerus were significantly associated with higher supraspinatus PDFF ( R = 0.44; P = .023). Cartilage T2 values did not correlate with muscle PDFF ( P > .05). CONCLUSION: MR imaging-derived RC muscle PDFF is associated with isometric strength independent of muscle atrophy and tendon rupture in shoulders with early and advanced degenerative changes. It therefore provides complementary, clinically relevant information in tracking RC muscle composition on a quantitative level.
引用
- Karampinos DC, Holwein C, Buchmann S, et al. Proton Density Fat-Fraction of Rotator Cuff Muscles Is Associated With Isometric Strength 10 Years After Rotator Cuff Repair: A Quantitative Magnetic Resonance Imaging Study of the Shoulder. Am J Sports Med. 2017. PMID: 28460192. doi:10.1177/0363546517703086
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。