高黏度骨水泥与标准胫骨托用于肥胖患者无菌性胫骨松动发生率低:至少2年随访
本研究纳入体重指数>35 kg/m²的1366例肥胖患者(1851膝),均使用高黏度骨水泥和标准胫骨托行初次全膝关节置换术,至少随访2年。平均随访5.4年时,仅1膝(0.054%)发生胫骨组件无菌性松动,膝关节活动度及各项评分均显著改善(P < .001)。作者认为标准胫骨组件和高黏度骨水泥可用于大多数患者,包括高危肥胖组,胫骨无菌性松动率低。
要点
- 肥胖患者(BMI>35 kg/m²)使用高黏度骨水泥和标准胫骨托行全膝关节置换术,平均随访5.4年胫骨无菌性松动发生率仅0.054%(1/1851膝)。
- 术后膝关节活动度平均增加3.3度,膝关节协会疼痛评分降低38.6分(50分制),临床评分提高52.2分,功能评分提高19.5分,UCLA活动评分提高0.9分,牛津膝关节评分提高15.7分,均P < .001。
- 作者结论认为标准胫骨组件和高黏度骨水泥可用于大多数患者,包括高危肥胖组,胫骨无菌性松动率低。
核心结论
- 标准胫骨组件和高黏度骨水泥可用于大多数患者,包括高危肥胖组,胫骨无菌性松动率低。
研究设计与样本
- 回顾性识别1366例肥胖患者(1851膝),体重指数>35 kg/m²,至少随访2年,均行初次全膝关节置换术,使用高黏度骨水泥和对称喷砂钴铬胫骨组件(40 mm柄)。
主要发现
- 平均随访5.4年,1851膝中仅1膝发生胫骨组件无菌性松动,发生率为0.054%。
- 膝关节活动度平均增加3.3度。
- 膝关节协会疼痛评分(50分制)降低38.6分,临床评分提高52.2分,功能评分提高19.5分,UCLA活动评分提高0.9分,牛津膝关节评分提高15.7分,所有改善均P < .001。
临床怎么用
- 作者认为标准胫骨组件和高黏度骨水泥可用于大多数患者,包括高危肥胖组,胫骨无菌性松动率低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Total knee arthroplasty is overall a very successful surgery, but complications do occur. These complications include aseptic loosening of the tibial component, and obese patients are among the highest risk group. High-viscosity cement (HVC) has been implicated as a possible cause for aseptic loosening of the tibial component. The purpose of this study was to evaluate the incidence of aseptic loosening of the tibial component in obese patients with the use of HVC and standard tibial tray. METHODS: We identified 1366 obese patients (1851 knees) with a body mass index >35 kg/m2 and 2-year minimum follow-up who underwent primary total knee arthroplasty using HVC and a symmetrical, grit-blasted, cobalt-chrome tibial component with 40-mm stem. Preoperative and postoperative range of motion, Knee Society (KS) scores, complications, and reoperations were evaluated. Specifically, we assessed the rate of tibial aseptic loosening. RESULTS: At a mean 5.4 years follow-up, only 1 in 1851 knees had aseptic loosening of the tibial component for an incidence of 0.054%. There was a mean increase of 3.3 degrees of knee range of motion. KS pain level decreased by 38.6 points (50 point scale). KS clinical scores improved by 52.2, Knee Society functional scores improved by 19.5, University of California, Los Angeles, activity score improved by 0.9, and Oxford Knee Score by 15.7. All these improvements were statistically significant with P < .001. CONCLUSION: Standard tibial components and HVC can be used in most patients, including the high-risk obese group, with low rates of tibial aseptic loosening.
引用
- Crawford DA, Berend KR, Nam D, et al. Low Rates of Aseptic Tibial Loosening in Obese Patients With Use of High-Viscosity Cement and Standard Tibial Tray: 2-Year Minimum Follow-Up. J Arthroplasty. 2017. PMID: 28511945. doi:10.1016/j.arth.2017.04.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。