中国与高加索人群全膝关节置换术模拟截骨前后三维骨形态学比较
研究对37例高加索人和50例中国人的膝关节CT三维重建模型进行测量,比较模拟全膝关节置换截骨前后的股骨与胫骨形态。结果显示中国人与高加索人各项测量均无显著差异,但中国女性模拟截骨前后股骨远端内外侧与前后径比值均小于中国男性。作者认为是否需为中国人群专门设计整套全膝关节部件尚未确定,但建议为中国女性设计专用股骨部件。
要点
- 中国人与高加索人膝关节三维骨形态测量均无显著差异。
- 中国女性模拟截骨前后股骨远端内外侧与前后径比值均小于中国男性。
- 作者建议为中国女性设计专用股骨部件,整套部件是否需专门设计尚未确定。
核心结论
- 为中国人群专门设计整套全膝关节部件的必要性仍未确定。
- 作者建议为中国女性设计专用股骨部件,因中国男性与中国女性截骨后股骨远端内外侧与前后径比值不同。
研究设计与样本
- 37例高加索人与50例中国人的膝关节接受计算机断层扫描(CT)检查。
- 应用Mimics软件重建三维骨模型,使用Geomagic Studio和Pro/ENGINEER测量三维膝关节模型尺寸及全膝关节置换术中模拟骨切除。
- 测量指标包括前后径(AP)、内外侧宽(ML)、切迹宽度、膝关节生理外翻角、胫骨后倾角及股骨、胫骨和截骨后股骨的内外侧与前后径比值。
- 统计分析采用SPSS for Windows的独立样本t检验和Pearson相关系数,P < .05认为有统计学意义。
主要发现
- 中国人与高加索人膝关节各项测量均无显著差异。
- 中国女性模拟截骨前股骨远端内外侧与前后径比值均值1.3 ± 0.1,模拟截骨后均值1.3 ± 0.1,均小于中国男性。
临床怎么用
- 作者建议为中国女性设计专用股骨部件。
- 作者认为为中国人群专门设计整套全膝关节部件的必要性仍未确定。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The bone morphologies of intact knees were measured and compared between Chinese and Caucasian populations. However, to assess if distinct designs of implants are necessary for the Chinese population owing to different morphologies and sizes, the knee measurements after osteotomy performed in total knee arthroplasty were evaluated. METHODS: Thirty-seven Caucasian and 50 Chinese patients' knees were examined using computed tomography scans. Mimics were applied to reconstruct 3-dimensional bone models. Dimensions of the 3-dimensional knee models and simulated bone resections during total knee arthroplasty were measured using Geomagic Studio and Pro/ENGINEER. The morphologic measurements of the native and resected femur and tibia included the anteroposterior (AP) depth, mediolateral (ML) width, notch width, knee physical valgus angle, tibial slope angle, and the ML-to-AP ratio of the femur, tibia, and resected femur. Statistical analysis was performed using the independent samples t test and the Pearson correlation coefficient in SPSS for Windows. Values of P < .05 were considered significant. RESULTS: No measurements were significantly different between the Chinese and Caucasian knees. However, the Chinese female showed significant differences compared with the Chinese male on distal femoral measurements both presimulated and postsimulated osteotomy such as a smaller mean ML-to-AP ratio in presimulated (1.3 ± 0.1) and postsimulated (1.3 ± 0.1) osteotomy. CONCLUSION: The necessity of designing a full set of total knee components specifically for the Chinese population is still undetermined. However, we suggest designing femoral components specific for the Chinese females because of different postosteotomy distal femoral ML-to-AP ratio between the Chinese males and the Chinese females.
引用
- Ma QL, Lipman JD, Cheng CK, et al. A Comparison Between Chinese and Caucasian 3-Dimensional Bony Morphometry in Presimulated and Postsimulated Osteotomy for Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28457760. doi:10.1016/j.arth.2017.03.069
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。