冲击植骨联合骨水泥型Lubinus SP II柄翻修全髋关节置换术后3至18年随访:临床、影像学及生存率分析与文献比较
本文报道69例(67例患者)因严重股骨骨溶解和假体松动行冲击植骨联合骨水泥型Lubinus SP II柄翻修的连续病例,回顾性分析68例,平均随访3至18年。随访时4个股骨假体(6%)翻修或判定失败,影像学结果优秀,Merle d'Aubignè-Postel评分从术前平均12.2改善至随访时17.5。作者认为该技术安全,假体周围骨折和脱位率低,中远期临床结果优秀,股骨出现活骨再生。
要点
- 冲击植骨联合骨水泥型Lubinus SP II柄翻修全髋关节置换术后中远期临床结果优秀。
- 68例随访中4个股骨假体(6%)翻修或判定失败,其中3例为机械失败、1例为脱位。
- 3个股杯(4%)因脱位翻修,3例(4%)因股骨远端假体周围骨折再手术且未更换假体柄。
核心结论
- 冲击植骨联合Lubinus SP II柄翻修全髋关节置换术安全,假体周围骨折和脱位率低,中远期临床结果优秀,股骨出现活骨再生。
研究设计与样本
- 回顾性分析连续69例股骨翻修(67例患者),均采用冲击植骨联合骨水泥型Lubinus SP II柄,平均年龄69岁(标准差9.9),68例完成随访(1例失访)。
- 翻修时所有病例均有明显股骨骨丢失,其中15例翻修原因为深部感染。
- 通过临床评分和影像学进行分析。
主要发现
- 随访时4个股骨假体(6%)翻修或判定失败,其中3例为机械失败、1例为脱位,无感染所致。
- 3个股杯(4%)因脱位翻修,其中1例同时更换假体柄。
- 3例(4%)因股骨远端假体周围骨折再手术,未更换假体柄。
- 影像学结果优秀,Merle d'Aubignè-Postel评分从术前平均12.2改善至随访时17.5。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We present the first medium- to long-term follow-up of revision total hip arthroplasty using impaction bone grafting (IBG) combined with the matte and collared Lubinus SP II stem for cases of severe osteolysis and stem loosening. METHODS: Sixty-nine femoral revisions were identified for 67 patients consecutively operated with revision femoral arthroplasty using IBG and a cemented Lubinus SP II stem. The mean age was 69 years (standard deviation, 9.9). We retrospectively analyzed 68 cases (1 was lost to follow-up). At the time of the revision surgery, all had substantial femoral bone loss. Fifteen of the revisions were performed due to deep infection. The patients were analyzed by clinical score and radiography. RESULTS: At follow-up, 4 femoral components (6%) had been rerevised or assessed as failure. Of these 4, 3 were assessed as mechanical failure, and 1 for dislocation; none was for infection. Three cups (4%) had been revised for dislocation; 1 of these also had a stem exchange. Three cases (4%) had been reoperated for a periprosthetic fracture in distal femur without stem exchange. Radiologic results were excellent and the clinical Merle d'Aubignè-Postel score had improved from a mean of 12.2 preoperatively to 17.5 at follow-up. CONCLUSION: IBG combined with the Lubinus SP II stem is safe and results in a low rate of periprosthetic fractures and dislocations. The medium- to long-term clinical result was excellent, with regeneration of living bone in the femur.
引用
- Stigbrand H, Ullmark G. A 3- to 18-Year Follow-Up of Revision Total Hip Arthroplasty With Impacted Bone Allografts and Cemented Lubinus SP II Stem. Clinical, Radiographic, and Survivorship Analysis With Comparison to the Literature. J Arthroplasty. 2017. PMID: 28529108. doi:10.1016/j.arth.2017.04.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。