文献速递关节外科

症状性金属对聚乙烯全髋关节置换术后机械辅助裂隙腐蚀中翻修前磁共振成像与术中发现的比较

Comparison of Pre-Revision Magnetic Resonance Imaging and Operative Findings in Mechanically Assisted Crevice Corrosion in Symptomatic Metal-on-Polyethylene Total Hip Arthroplasties.
PubMed 文献 · J Arthroplasty · 2017-03-18

该研究纳入20例因症状性机械辅助裂隙腐蚀(MACC)行翻修的全髋关节置换术(THA)患者,比较术前金属伪影减少序列(MARS)磁共振成像(MRI)与术中发现的关联。结果显示MARS MRI的复杂滑膜炎、假包膜增厚和关节外积液扩展与软组织损伤分级及桁端损伤强相关,骨髓水肿与骨坏死强相关。作者认为MARS MRI是评估金属对聚乙烯THA后血清钴升高患者的优良诊断工具。

要点

  • MARS MRI复杂滑膜炎、假包膜增厚和关节外积液扩展与手术软组织损伤分级及桁端损伤强相关。
  • 骨髓水肿与术中骨坏死强相关。
  • 作者认为MARS MRI是评估金属对聚乙烯THA后血清钴升高患者的优良诊断工具。

核心结论

  • MARS MRI是评估金属对聚乙烯THA后血清钴升高患者的优良诊断工具。
  • 存在复杂滑膜炎、假包膜增厚、骨髓水肿和关节外积液的患者应强烈考虑翻修手术。

研究设计与样本

  • 研究为队列研究,纳入20例连续因症状性MACC且无其他相关骨科诊断而行翻修THA的患者。
  • 比较术前MARS MRI与术中发现的关联,术中评估包括软组织和骨、积液存在与位置、外展肌断裂、复合组织损伤分级及翻修时假体桁端损伤。

主要发现

  • MARS MRI复杂滑膜炎、假包膜增厚和关节外积液扩展各与手术软组织损伤分级及桁端损伤强相关。
  • 骨髓水肿与术中骨坏死强相关。

临床怎么用

  • 作者认为MARS MRI是评估金属对聚乙烯THA后血清钴升高患者的优良诊断工具。
  • 作者建议存在复杂滑膜炎、假包膜增厚、骨髓水肿和关节外积液的患者应强烈考虑翻修手术。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Failed total hip arthroplasty (THA) caused by mechanically assisted crevice corrosion (MACC) has serious consequences-notably, adverse local tissue reactions. Metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has been used to evaluate failed THA for other reasons but has not been assessed for the analysis of cases of MACC in the setting of metal-on-polyethylene arthroplasties. METHODS: We examined the correlation between preoperative MARS MRI and surgical findings in a cohort of 20 consecutive patients undergoing revision THA for symptomatic MACC without other associated orthopedic diagnoses. Surgical findings included soft tissue and bone evaluation, presence and location of fluid, abductor disruption, composite tissue damage grade, and prosthesis trunnion damage at the time of revision. RESULTS: MARS MRI complex synovitis, thickened pseudocapsule, and extra-articular fluid extension each strongly correlated with both the soft-tissue damage grade and trunnion damage noted at surgery. Bone marrow edema was also found to strongly correlate with bone necrosis intraoperatively. CONCLUSION: MARS MRI is an excellent diagnostic tool for evaluation of patients with elevated serum Co after metal-on-polyethylene THA. Patients with complex synovitis, a thick pseudocapsule, bone marrow edema, and extra-articular fluid should strongly consider revision surgery.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Morozov PP, Sana M, McGrory BJ, et al. Comparison of Pre-Revision Magnetic Resonance Imaging and Operative Findings in Mechanically Assisted Crevice Corrosion in Symptomatic Metal-on-Polyethylene Total Hip Arthroplasties. J Arthroplasty. 2017. PMID: 28479059. doi:10.1016/j.arth.2017.03.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。