血清金属水平诊断金属对聚乙烯全髋关节置换术后腐蚀继发不良局部组织反应
本研究回顾447例在本院检测血清金属水平的连续患者,其中64例金属对聚乙烯全髋关节置换术后经轴向影像或再手术确认不良局部组织反应(ALTR)状态。结果显示血清钴水平(阈值≥1.0 ng/mL)诊断ALTR的曲线下面积为99%,敏感度100%、特异度90%;铬及钴铬比亦有诊断价值。作者认为血清钴水平是识别ALTR的最佳检测。
要点
- 血清钴≥1.0 ng/mL诊断ALTR的AUC为99%,敏感度100%、特异度90%。
- 血清铬≥0.15 ng/mL诊断ALTR的AUC为87%,敏感度100%、特异度50%。
- 钴铬比阈值1.4诊断ALTR的AUC为90%,敏感度93%、特异度70%。
核心结论
- 作者认为在本院经验中,血清钴水平阈值1.0 ng/mL是识别金属对聚乙烯全髋关节置换术后ALTR的最佳检测。
- 作者认为血清铬水平及钴铬比亦有诊断价值。
研究设计与样本
- 回顾性分析447例在本院检测血清金属水平的连续患者,其中64例金属对聚乙烯全髋关节置换术后经轴向影像或再手术确认ALTR状态。
- 采用受试者工作特征曲线确定优化敏感度的截断阈值,并评估诊断试验性能。
主要发现
- 64例中44例(69%)ALTR阳性。
- 血清钴水平诊断ALTR的AUC为99%,阈值≥1.0 ng/mL时敏感度100%、特异度90%、阳性预测值96%、阴性预测值100%。
- 血清铬水平诊断ALTR的AUC为87%,阈值≥0.15 ng/mL时敏感度100%、特异度50%、阳性预测值81%、阴性预测值100%。
- 钴铬比诊断ALTR的AUC为90%,阈值1.4时敏感度93%、特异度70%、阳性预测值87%、阴性预测值82%。
关键数值与推荐
- 血清钴阈值≥1.0 ng/mL:AUC 99%,敏感度100%,特异度90%,阳性预测值96%,阴性预测值100%。
- 血清铬阈值≥0.15 ng/mL:AUC 87%,敏感度100%,特异度50%,阳性预测值81%,阴性预测值100%。
- 钴铬比阈值1.4:AUC 90%,敏感度93%,特异度70%,阳性预测值87%,阴性预测值82%。
临床怎么用
- 作者认为血清钴水平阈值1.0 ng/mL是识别金属对聚乙烯全髋关节置换术后ALTR的最佳检测。
- 作者认为血清铬水平及钴铬比亦有诊断价值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Recently, corrosion at the head-neck junction in metal-on-polyethylene bearing surface total hip arthroplasty (THA) has been recognized as a cause of adverse local tissue reactions (ALTRs). Serum metal levels have been advocated as a tool for the diagnosis of ALTR; however, no prior studies have specifically examined their utility. The purpose of this study was to determine the optimal cutoff values for serum cobalt and chromium levels in diagnosing ALTR after metal-on-polyethylene bearing surface THA. METHODS: We reviewed 447 consecutive patients with serum metal levels tested at our institution and identified 64 patients with a metal-on-polyethylene bearing who had axial imaging or underwent reoperation to confirm the presence or absence of ALTR. Receiver-operating characteristic curves were produced to identify cutoff thresholds to optimize sensitivity, and diagnostic test performance was characterized. RESULTS: Forty-four of the 64 patients (69%) were positive for an ALTR. The best test for the diagnosis of ALTR was the serum cobalt level (area under the curve [AUC] = 99%). A threshold cutoff of ≥1.0 ng/mL had a sensitivity of 100%, specificity of 90%, positive predictive value (PPV) of 96%, and negative predictive value (NPV) of 100%. Serum chromium levels were also diagnostic (AUC = 87%). A threshold cutoff of ≥0.15 ng/mL had a sensitivity of 100%, specificity of 50%, PPV of 81%, and NPV of 100%. Finally, serum cobalt-to-chromium ratio was also helpful for diagnosis (AUC = 90%). A threshold cutoff value of 1.4 for the cobalt-to-chromium ratio offered a sensitivity of 93%, specificity of 70%, PPV of 87%, and NPV of 82%. CONCLUSION: Measurement of serum cobalt level with a threshold value of 1.0 ng/mL in our experience is the best test for identifying the presence of ALTR in patients with a metal-on-polyethylene THA. Measurement of chromium level and the ratio of cobalt-to-chromium levels are also of value.
引用
- Fillingham YA, Della Valle CJ, Bohl DD, et al. Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions Secondary to Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 28511949. doi:10.1016/j.arth.2017.04.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。