多孔钽髋臼杯与增强块重建在复杂翻修全髋关节置换术中的至少五年结局

Minimum Five-Year Outcomes with Porous Tantalum Acetabular Cup and Augment Construct in Complex Revision Total Hip Arthroplasty.
PubMed 文献 · J Bone Joint Surg Am · 2017-01-01

本研究回顾性分析2000至2007年间单中心使用多孔钽增强块行翻修全髋关节置换术的84例患者(85髋),其中57例(58髋)完成至少5年临床和影像学随访。主要结论为:以无菌性松动需再翻修为失败标准,5年生存率为97%,髋关节功能维持满意;术前骨盆不连续者中6/11髋出现失败或3区透亮线。

要点

  • 多孔钽髋臼杯与增强块重建在复杂翻修全髋中5年生存率达97%。
  • 58髋中2髋(3%)因无菌性松动失败需再翻修。
  • 6髋(10%)出现假体-骨界面DeLee-Charnley 3区透亮线。

核心结论

  • 以无菌性松动需再翻修为失败标准,本队列在索引翻修术后至少5年生存率为97%,髋关节功能维持满意。
  • 11髋术前骨盆不连续者中6髋失败或出现3区透亮线,被认为存在未来翻修风险。
  • 作者认为骨盆不连续应促使考虑附加固定或使用替代技术。

研究设计与样本

  • 回顾性研究,2000至2007年间单中心84例患者(85髋)使用多孔钽增强块行翻修全髋关节置换术。
  • 57例患者(58髋)完成至少5年临床和影像学随访。
  • 翻修时多数髋臼缺损为Paprosky 3A型(28/58,48%)或3B型(22/58,38%);11髋(19%)存在术前骨盆不连续。
  • 临床评估采用Mayo髋关节评分,术后X线评估假体稳定性、透亮线位置及骨盆不连续愈合情况。
  • 证据等级:治疗性IV级。

主要发现

  • 58髋中2髋(3%)因髋臼组件无菌性松动而失败,需再翻修。
  • 58髋中6髋(10%)在DeLee-Charnley 3区出现假体-骨界面透亮线。
  • 再翻修的1髋及6髋3区透亮线中的5髋,在索引翻修时存在骨盆不连续。
  • 平均术前Mayo髋关节评分为35.7,术后3个月提高至61.9,至少5年随访时为61.7。

临床怎么用

  • 作者认为骨盆不连续应促使考虑附加固定或使用替代技术。

局限性

  • 本研究为单中心回顾性研究。
  • 85髋中仅58髋完成至少5年随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of a trabecular metal revision shell with metal augmentation to fill segmental or irregular defects during complex revision hip arthroplasty has been shown to provide good short-term results in prior published series. Longer-term results of the several cup-augment constructs used clinically are not known. The objective of this study was to report, with minimum 5-year radiographic and clinical follow-up, the outcome of these various constructs in revision total hip arthroplasty. METHODS: Eighty-four patients (85 hips) underwent revision total hip arthroplasty with use of porous tantalum augments between 2000 and 2007 at a single institution and were retrospectively reviewed. Fifty-seven of the patients (58 hips) had clinical and radiographic follow-up at a minimum of 5 years. At the time of revision, the majority of the hips had acetabular defects classified as Paprosky Type 3A (28 of 58, 48%) or Type 3B (22 of 58, 38%). Eleven (19%) of the hips also had preoperative pelvic discontinuity. All hips were assessed clinically at a minimum of 5 years with use of the Mayo hip score. Postoperative radiographs were reviewed for implant stability, the presence and location of radiolucent lines and healing of the discontinuity if present. RESULTS: In 2 (3%) of the 58 hips, the constructs failed because of aseptic loosening of the acetabular component and re-revision was indicated. Six (10%) of the 58 hips demonstrated a radiolucent line between the trabecular metal shell and bone in DeLee and Charnley zone 3. In 1 hip that underwent re-revision and in 5 of the 6 hips with a zone-3 radiolucency, a pelvic discontinuity was present at the time of the index revision. The mean preoperative Mayo hip score was 35.7, which improved to 61.9 at 3 months and was 61.7 at the minimum 5-year follow-up. CONCLUSIONS: With failure defined as aseptic loosening requiring repeat revision surgery, this cohort demonstrated 97% survivorship and maintained satisfactory hip function at the minimum 5 years after the index revision surgery. Six of the 11 hips with preoperative pelvic discontinuity either failed or developed a radiolucency in zone 3 and are considered at risk for future revision. Pelvic discontinuity should prompt consideration of the addition of adjunctive fixation or the use of alternative techniques. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.