保留与不保留肱骨柄翻修反式全肩关节置换术:可转换平台柄的作用
多中心回顾性分析102例解剖型肩关节置换翻修反式全肩关节置换术,73例更换肱骨柄、29例保留可转换平台柄,保留组手术时间更短、估计失血量更少、术中并发症率更低(0%对15%,p=0.027)。
要点
- 保留组手术时间130±48分钟,短于更换组195±58分钟(p<0.001)。
- 保留组估计失血量292±118 mL,少于更换组492±334 mL(p=0.034)。
- 保留组主动外旋26°±23°,优于更换组11°±23°(p=0.006)。
核心结论
- 使用可转换平台肱骨柄的肩关节置换系统在翻修反式全肩关节置换术时,保留固定良好、位置良好的肱骨柄具有优势,并发症显著更少、失血和手术时间显著减少(p<0.050)。
研究设计与样本
- 多中心回顾性分析,纳入102例连续肩关节(102例患者),均为解剖型肩关节置换翻修反式全肩关节置换术。
- 其中73例翻修时更换肱骨柄(更换组),29例保留可转换平台肱骨组件(保留组)。
- 比较两组患者人口学资料、手术时间、血液管理、活动度、并发症和患者报告结局。
主要发现
- 保留组手术时间平均130±48分钟,更换组195±58分钟(p<0.001)。
- 保留组估计失血量292±118 mL,更换组492±334 mL(p=0.034)。
- 保留组术中并发症率0%,更换组15%(p=0.027)。
- 保留组主动外旋26°±23°,更换组11°±23°(p=0.006);主动前屈112°±37°对96°±33°(p=0.055)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Revision shoulder arthroplasty is a technically challenging procedure. It is associated with increased blood loss and operative time, and it frequently necessitates revision implants, augments, and bone-grafting. Shoulder arthroplasty systems with a convertible-platform humeral stem have been developed to reduce the complexity of revision procedures by eliminating the need for humeral component explantation when converting from anatomic shoulder arthroplasty (hemiarthroplasty or total shoulder arthroplasty) to reverse total shoulder arthroplasty (rTSA). METHODS: A multicenter, retrospective analysis involving 102 consecutive shoulders (102 patients) that underwent revision of an anatomic shoulder arthroplasty to an rTSA was conducted. During the revision, 73 of the shoulders needed exchange of the humeral stem (the exchange group) and 29 had retention of a convertible-platform humeral component (the retention group). Patient demographics, operative time, blood management, range of motion, complications, and patient-reported outcomes were compared between the 2 groups. RESULTS: Patients with retention had significantly shorter operative time (mean and standard deviation, 130 ± 48 versus 195 ± 58 minutes; p < 0.001) and lower estimated blood loss (292 ± 118 versus 492 ± 334 mL; p = 0.034). The rate of intraoperative complications was lower in the retention group (0% versus 15%; p = 0.027). Patients with retention had slightly better postoperative range of motion (active external rotation, 26° ± 23° versus 11° ± 23° [p = 0.006]; active forward elevation, 112° ± 37° versus 96° ± 33° [p = 0.055]). CONCLUSIONS: Shoulder arthroplasty systems that utilize a convertible-platform humeral stem offer an advantage for rTSA conversion in that a well-fixed, well-positioned humeral stem can be retained. There were significantly fewer complications as well as significantly decreased blood loss and operative time when a convertible-platform stem was utilized (p < 0.050). LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
- Crosby LA, Wright TW, Yu S, et al. Conversion to Reverse Total Shoulder Arthroplasty with and without Humeral Stem Retention: The Role of a Convertible-Platform Stem. J Bone Joint Surg Am. 2017. PMID: 28463917. doi:10.2106/JBJS.16.00683
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。