本研究分析了来自2家制造商的166个取出的股骨头,按头尺寸、桁架设计、制造商和关节类型(金属对金属MoM vs 金属对聚乙烯MoP)分组,用坐标测量机测量腐蚀并评估材料损失。结果显示,MoP关节的桁架材料损失平均比MoM关节少5倍,且材料损失与体内时间的相关性仅见于MoP关节。

要点

  • MoP关节的桁架材料损失平均比MoM关节少5倍,两家制造商结果一致。
  • 大号模块头(>40 mm)与36-mm MoM髋桁架之间材料损失无差异。
  • 材料损失超过检测限的植入物中,仅MoP关节显示材料损失与体内时间相关。

核心结论

  • MoP轴承对取出的股骨头材料损失程度低于MoM轴承对,且不依赖于头直径。
  • 仅在MoP轴承中观察到体内时间效应。

研究设计与样本

  • 研究分析了来自2家制造商的166个取出的股骨头。
  • 根据头尺寸、桁架设计、制造商和关节类型(MoM vs MoP)创建了四个队列。
  • 使用坐标测量机测量腐蚀,并用MATLAB评估材料损失。

主要发现

  • 对于两家制造商,MoP关节取出的股骨头桁架材料损失平均比MoM关节少5倍。
  • 大号模块头(>40 mm)与36-mm MoM髋桁架之间材料损失无差异。
  • 材料损失超过检测限的植入物中,仅MoP关节显示材料损失与体内时间相关。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Trunnion tribocorrosion in total hip arthroplasties is concerning, but retrieval studies often are subjective or lack comparison groups. Quantitative comparisons of clinically relevant implants are required. The purpose of this investigation was to evaluate material loss in metal-on-metal (MoM) and metal-on-polyethylene (MoP) total hip articulations while controlling for trunnion design and head size. METHODS: The 166 retrieved femoral heads from 2 manufacturers were analyzed. Four cohorts based on head size, trunnion design, manufacturer, and articulation type (MoM vs MoP) were created. Corrosion was measured by a coordinate measurement machine, and material loss was assessed (MATLAB). RESULTS: Retrieved femoral heads from MoP articulations had 5 times less trunnion material loss than MoM articulations, on average, for both manufacturers. There was no difference in material loss between large modular head (>40 mm) and 36-mm MoM hip trunnion. Implants with a material loss above the detectable limit demonstrated a correlation with time in vivo only in MoP articulations. CONCLUSION: Retrieved femoral heads from MoP bearing couples had a lower magnitude of material loss than MoM couples, independent of head diameter. A time in vivo effect was only seen in MoP bearings.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Lanting BA, Teeter MG, Howard JL, et al. Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 28483210. doi:10.1016/j.arth.2017.03.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。