研究比较导航与传统陶瓷对陶瓷全髋关节置换术(CoC THA)的杂音发生率,共评估375例(导航组202例、传统组173例)。年龄<65岁患者杂音发生率显著更高(22.4% vs 6.1%,P<.001)。在<65岁且使用32mm股骨头的亚组中,传统组杂音发生率显著高于导航组(28% vs 10%,P=.005),传统组相对导航组的杂音相对风险为2.7(P=.01)。

要点

  • 年龄<65岁患者CoC THA后杂音发生率显著高于≥65岁患者(22.4% vs 6.1%,P<.001)。
  • 在<65岁、32mm股骨头亚组中,传统组杂音发生率显著高于导航组(28% vs 10%,P=.005)。
  • 出现吱吱声的THA患者髋臼杯前倾角显著低于无杂音患者(13.4°±5.2° vs 17.6°±6.9°,P=.01)。

核心结论

  • 导航CoC THA发生杂音的可能性比传统CoC THA低2.7倍。
  • 出现吱吱声的THA患者髋臼杯前倾角显著低于无杂音患者。
  • 年龄<65岁患者CoC THA后杂音发生率显著更高。

研究设计与样本

  • 研究纳入2009年3月至2012年8月期间接受CoC THA的所有患者,通过电话或邮寄访谈获取髋关节杂音信息。
  • 共评估375例使用同一假体的CoC THA(导航组202例,传统组173例)。
  • 为比较杂音发生率,选取年龄<65岁且使用32mm股骨头的亚组(导航组68例,传统组118例)。

主要发现

  • 年龄<65岁患者杂音发生率显著高于≥65岁患者(22.4% vs 6.1%;P<.001)。
  • 在<65岁、32mm股骨头亚组中,传统组总体杂音发生率显著高于导航组(28% vs 10%;P=.005)。
  • 传统组相对导航组的杂音相对风险为2.7(P=.01),吱吱声相对风险为1.9(P=.2)。
  • 出现吱吱声的THA患者髋臼杯前倾角显著低于无杂音患者(13.4°±5.2° vs 17.6°±6.9°;P=.01)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Noise after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a well-recognized problem. Computer navigation has been shown to achieve desired implant orientation. Our aim was (1) to compare the incidence of noise between navigated and conventional CoC THAs and (2) to determine the factors associated with noise. METHODS: All patients undergoing CoC THA between March 2009 and August 2012 were considered for this study. Information regarding hip noise was obtained via telephone or postal interview. A comparable cohort of patients in navigated and conventional groups was used to evaluate the incidence of noise. RESULTS: A total of 375 CoC THAs using the same implant (202 navigated and 173 conventional) were evaluated. Patients <65 years of age had significantly greater incidence of noise (22.4% vs 6.1%; P < .001). To ensure similarity, a subgroup of cohort <65 years and a 32-mm head size was used to compare the incidence of noise between the navigated (68 THAs) and conventional (118 THAs) groups. Overall incidence of noise was significantly greater in the conventional group (28%) as compared with the navigated group (10%; P = .005). The relative risk of noise for the conventional vs the navigated group was 2.7 (P = .01), and for squeaking was 1.9 (P = .2). Squeaking THAs had significantly lower cup anteversion (13.4° ± 5.2°) as compared with the silent THAs (17.6° ± 6.9°; P = .01). CONCLUSION: Navigated CoC THAs were 2.7× less likely to have noise as compared with the conventional ones. Squeaking THAs had significantly lower cup anteversion as compared with the silent ones. Patients of age <65 years had significantly greater incidence of noise after CoC THA.