文献速递关节外科

髋膝关节置换计算机辅助导航中导针相关并发症

Pin Site Complications Associated With Computer-Assisted Navigation in Hip and Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-04-20

该回顾性队列研究纳入单一机构3年内839例导航辅助髋膝关节置换的3136个导针位点,导针并发症发生率为每位点0.16%、每例患者0.60%,共5例并发症(3例感染、1例神经失用、1例缝线脓肿),均经非手术治疗缓解;经皮质或近皮质钻孔可能与感染相关,未来研究应量化该效应。

要点

  • 导航辅助髋膝关节置换的导针并发症发生率低,为每位点0.16%、每例患者0.60%。
  • 共报告5例并发症:3例感染、1例神经失用、1例缝线脓肿,均经非手术治疗缓解。
  • 经皮质或近皮质钻孔可能是导针部位感染的危险因素,未来研究应量化该效应。

核心结论

  • 导航辅助关节置换所需导针的并发症发生率低。
  • 经皮质或近皮质钻孔可能是导针部位感染的危险因素,未来研究应量化该效应。

研究设计与样本

  • 回顾性队列研究,纳入单一机构3年内所有导航辅助髋膝关节置换,共839例患者、3136个导针位点。

主要发现

  • 共报告5例导针并发症,并发症发生率为每位点0.16%、每例患者0.60%。
  • 单髁膝关节置换的每例手术并发症率(0.64%)略高于髌股关节置换(0%)和全髋关节置换(0.46%),但无统计学显著差异。
  • 并发症包括3例感染、1例神经失用和1例缝线脓肿,未报告经导针部位的假体周围骨折。
  • 所有并发症均经非手术治疗缓解,感染需口服抗生素,其中2例与经皮质钻孔相关、第3例与近皮质钻孔相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There has been a great increase in the use of navigation technology in joint arthroplasty. In most types of navigation-assisted surgery, several temporary navigation pins are placed in the patient. Goals of this study are (1) to identify complications and (2) risk factors associated with placement of these pins. METHODS: This is a retrospective cohort study of all navigation-assisted hip and knee arthroplasty performed a single institution over a 3-year period. Records were reviewed and outcome measures were tabulated in a database. Complications included in the database were pin site infection, deep prosthetic joint infection, neurologic injury, vascular injury, and fracture through a pin site. RESULTS: A total of 3136 pin sites in 839 patients were included in the study. Five pin site complications were reported with a complication rate of 0.16% per pin site and 0.60% per patient. The complications-per-procedure were slightly higher for unicondylar knee arthroplasty (0.64%) compared with patellofemoral arthroplasty (0%) and total hip arthroplasty (0.46%), but not statistically significant. There were three infections, one neuropraxia, and one suture abscess. No periprosthetic fractures through a pin site were reported. All complications were resolved with nonoperative treatment. The infections required oral antibiotics, and were associated with transcortical drilling in two cases and juxtacortical drilling in the third. CONCLUSION: Pins required for navigation-assisted arthroplasty have a low complication rate. Transcortical or juxtacortical drilling may be a risk factor for pin site infection; future studies should be directed at quantifying this effect.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kamara E, Berliner ZP, Hepinstall MS, et al. Pin Site Complications Associated With Computer-Assisted Navigation in Hip and Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28522245. doi:10.1016/j.arth.2017.03.073

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。