文献速递关节外科

非感染性翻修全髋关节置换术中的模块化带槽锥形柄

Modular Fluted Tapered Stems in Aseptic Revision Total Hip Arthroplasty.
PubMed 文献 · J Bone Joint Surg Am · 2017-01-01

本研究纳入519例非感染性股骨翻修使用模块化带槽锥形柄的病例,平均随访4.5年(范围2至14年)。Harris髋关节评分(HHS)由术前51分显著提高至术后2年76分(p<0.001),末次随访维持75分;10年生存率以任何原因翻修为终点为96%,以任何再手术为终点为90%。作者认为该柄在各类术前骨缺损中均获得高骨整合率与持续临床评分改善,并发症率可接受。

要点

  • 519例非感染性股骨翻修使用模块化带槽锥形柄,平均随访4.5年(范围2至14年)。
  • HHS由术前51分升至2年76分(p<0.001),末次随访75分。
  • 10年生存率任何原因翻修96%、任何再手术90%,术后并发症12%。

核心结论

  • 在519例的大系列中,模块化带槽锥形柄股骨翻修在末次随访时提供高骨整合率和持续的临床评分改善。
  • 在所有术前骨缺损类别中均获得高植入物固定成功率,并发症率可接受。
  • 证据等级为治疗性IV级。

研究设计与样本

  • 回顾性识别519例非感染性股骨翻修,术中均使用模块化带槽锥形柄。
  • 评估临床结果、Kaplan-Meier生存率、影像学结果和并发症。
  • 翻修时平均年龄70岁,平均BMI 29 kg/m²,平均随访4.5年(范围2至14年)。

主要发现

  • HHS由术前平均51分显著提高至2年时平均76分(p<0.001),末次随访维持平均75分。
  • 末次随访时共行16例股骨翻修:无菌性松动6例、感染4例、不稳3例、假体周围骨折2例、柄断裂1例。
  • 10年生存率以任何原因翻修为终点为96%,以任何再手术为终点为90%。
  • 末次随访时存活且未翻修的患者中12例出现柄下沉,除1例外其余下沉后均稳定。
  • 术后并发症见于12%的病例;因股骨部件松动行再次翻修与术前骨缺损类别或患者人口学因素不相关。

关键数值与推荐

  • 10年生存率:任何原因翻修终点96%,任何再手术终点90%。
  • 术后并发症率12%。
  • 16例股骨翻修的原因构成:无菌性松动6例、感染4例、不稳3例、假体周围骨折2例、柄断裂1例。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Modular fluted tapered stems have become the most commonly employed category of femoral component in revision hip arthroplasty in North America as a result of favorable early results and simplicity of use. Despite wide adoption, the majority of published data are limited to relatively small series with modest follow-up. The goal of the current study was to determine the success rate and factors associated with success, failure, and complications of the use of modular fluted tapered stems in aseptic revision total hip arthroplasties (THAs) in a large patient cohort. METHODS: We identified 519 aseptic femoral revisions during which a modular fluted tapered stem was utilized. Clinical outcomes, Kaplan-Meier survivorship, radiographic outcomes, and complications were assessed. The mean age at revision arthroplasty was 70 years, the mean body mass index (BMI) was 29 kg/m, and the mean duration of follow-up was 4.5 years (range, 2 to 14 years). RESULTS: The mean Harris hip score (HHS) improved significantly from 51 points preoperatively to 76 points at 2 years (p < 0.001). This improvement was maintained at the last follow-up evaluation (mean HHS = 75 points). At the time of the most recent follow-up, 16 femoral revisions had been performed: 6 because of aseptic loosening, 4 because of infection, 3 because of instability, 2 because of periprosthetic fracture, and 1 because of stem fracture. The 10-year survivorship was 96% with revision for any reason as the end point and 90% with any reoperation as the end point. Of the patients who were alive and had not undergone revision at the time of final follow-up, 12 had stem subsidence but all but 1 of these stems had stabilized after subsiding. Postoperative complications were noted in 12% of the cases. Repeat revision due to femoral component loosening was not correlated with the preoperative bone-loss category or patient demographic factors. CONCLUSIONS: In this large series, femoral revision with a modular fluted tapered stem provided a high rate of osseointegration and sustained improvement in clinical scores at the time of the last follow-up. There was also a high rate of successful implant fixation across all categories of preoperative bone loss and an acceptable rate of complications. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Abdel MP, Cottino U, Larson DR, et al. Modular Fluted Tapered Stems in Aseptic Revision Total Hip Arthroplasty. J Bone Joint Surg Am. 2017. PMID: 28509828. doi:10.2106/JBJS.16.00423

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。