文献速递关节外科

全髋关节置换术后晚期脱位:摩擦界面是否为影响因素?

Late Dislocations After Total Hip Arthroplasty: Is the Bearing a Factor?
PubMed 文献 · J Arthroplasty · 2017-04-27

本研究基于澳大利亚骨科协会国家关节置换登记系统,纳入192275例初次全髋关节置换,比较金属对交联聚乙烯、陶瓷对交联聚乙烯与陶瓷对陶瓷三种摩擦界面的晚期脱位翻修率。13年累积脱位翻修率分别为1.2%、1.0%和0.9%,金属对交联聚乙烯风险高于其他两种;按股骨头尺寸分层后,28 mm和32 mm组无差异,36 mm组金属对交联聚乙烯脱位率更高。结论认为摩擦界面对脱位翻修影响很小。

要点

  • 13年累积脱位翻修率:金属对交联聚乙烯1.2%,陶瓷对交联聚乙烯1.0%,陶瓷对陶瓷0.9%。
  • 金属对交联聚乙烯脱位翻修风险高于陶瓷对交联聚乙烯和陶瓷对陶瓷。
  • 28 mm和32 mm股骨头尺寸下三种摩擦界面脱位翻修风险无差异;36 mm时金属对交联聚乙烯脱位率更高。

核心结论

  • 摩擦界面对全髋关节置换术后脱位翻修的影响很小。

研究设计与样本

  • 基于澳大利亚骨科协会国家关节置换登记系统的数据,采用Kaplan-Meier法估计不同摩擦界面的累积脱位翻修率。
  • 共纳入192275例全髋关节置换,其中金属对交联聚乙烯101915例、陶瓷对交联聚乙烯30256例、陶瓷对陶瓷60104例。

主要发现

  • 13年累积脱位翻修率:金属对交联聚乙烯1.2%(95%CI 1.1-1.3),陶瓷对交联聚乙烯1.0%(95%CI 0.7-1.4),陶瓷对陶瓷0.9%(95%CI 0.8-1.1)。
  • 金属对交联聚乙烯相比陶瓷对交联聚乙烯和陶瓷对陶瓷,脱位翻修风险增加。
  • 按股骨头尺寸分层,28 mm和32 mm尺寸下三种摩擦界面脱位翻修风险无差异;36 mm尺寸下金属对交联聚乙烯脱位率高于其他材料。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Dislocation is a leading cause of revision after primary total hip arthroplasty (THA). Although more common in the first few years after the procedure, dislocation can occur at any time. This study investigated the difference in late dislocation in ceramic-on-ceramic (CoC) bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings in THA. METHODS: Data were used from the Australian Orthopaedic Association National Joint Replacement Registry, and the cumulative percent revision for dislocation was estimated using the Kaplan-Meier method for the different bearing surfaces. There were 192,275 THAs included in the study with 101,915 metal-on-cross-linked polyethylene (MoXLPE), 30,256 ceramic-on-cross-linked polyethylene (CoXLPE), and 60,104 CoC. RESULTS: The cumulative percent revision for dislocation at 13 years for MoXLPE, CoXLPE, and CoC groups was 1.2 (95% confidence interval [CI], 1.1-1.3), 1.0 (95% CI, 0.7-1.4), and 0.9 (95% CI, 0.8-1.1), respectively. There was an increased risk of revision for dislocation for MoXLPE compared with CoXLPE and CoC. When stratified for head size, there was no difference in the risk of revision for dislocation between MoXLPE, CoXLPE, and CoC in the 28- and 32-mm head sizes. With a head size of 36 mm, MoXLPE had a higher rate of dislocation compared with other materials. CONCLUSION: Bearing surface has little impact on revision for dislocation.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Shah SM, Walter WL, Tai SM, et al. Late Dislocations After Total Hip Arthroplasty: Is the Bearing a Factor? J Arthroplasty. 2017. PMID: 28529109. doi:10.1016/j.arth.2017.04.037

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。