文献速递小儿骨科骨质疏松与代谢性骨病

脑性瘫痪儿童的功能性肌肉-骨骼单元

The functional muscle-bone unit in children with cerebral palsy.
PubMed 文献 · Osteoporos Int · 2017-04-01

该单中心回顾性分析纳入297例脑性瘫痪(CP)儿童的全身体双能X线吸收测定(DXA)扫描,比较年龄和身高校正的骨矿物含量(BMC)及面积骨密度(aBMD)与功能性肌肉-骨骼单元诊断算法(FMBU-A)阳性结果患病率。年龄校正BMC和aBMD阳性率分别为33.3%和50.8%,身高校正分别为16.8%和36.0%,FMBU-A阳性率分别为8.8%和14.8%,均显著降低(p < 0.001)。作者建议在评估CP儿童骨骼健康时应用FMBU-A。

要点

  • 年龄校正BMC和aBMD阳性率分别为33.3%和50.8%,身高校正分别为16.8%和36.0%。
  • 应用FMBU-A后BMC和aBMD阳性率分别为8.8%和14.8%,显著低于年龄和身高校正法(p < 0.001)。
  • 作者建议评估CP儿童骨骼健康时应用FMBU-A。

核心结论

  • 作者认为,仅使用年龄和身高校正的BMC和aBMD会高估CP儿童骨骼健康缺陷的患病率。
  • 应用FMBU-A后阳性结果患病率显著降低。
  • 作者建议在评估CP儿童骨骼健康时应用FMBU-A。

研究设计与样本

  • 本研究为单中心回顾性分析,纳入297例脑性瘫痪(CP)儿童的全身体DXA扫描。
  • 计算年龄和身高校正的BMC和aBMD(定义为低于P3百分位)以及FMBU-A的阳性结果患病率。

主要发现

  • 年龄校正BMC阳性率为33.3%,aBMD阳性率为50.8%。
  • 身高校正BMC阳性率为16.8%,aBMD阳性率为36.0%。
  • FMBU-A评估BMC和aBMD的阳性率分别为8.8%和14.8%,显著低于年龄和身高校正法(p < 0.001)。

关键数值与推荐

  • 年龄和身高校正BMC及aBMD阳性定义为低于P3百分位。
  • FMBU-A阳性率BMC 8.8%、aBMD 14.8%,显著低于年龄和身高校正法(p < 0.001)。

临床怎么用

  • 作者建议在评估CP儿童骨骼健康时应用FMBU-A。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Our results suggest that the prevalence of bone health deficits in children with CP was overestimated, when using only age- and height-adjusted bone mineral content (BMC) and areal bone mineral density (aBMD). When applying the functional muscle-bone unit diagnostic algorithm (FMBU-A), the prevalence of positive results decreased significantly. We recommend applying the FMBU-A when assessing bone health in children with CP. INTRODUCTION: The prevalence of bone health deficits in children with cerebral palsy (CP) might be overestimated because age- and height-adjusted reference percentiles for bone mineral content (BMC) and areal bone mineral density (aBMD) assessed by dual-energy X-ray absorptiometry (DXA) do not consider reduced muscle activity. The aim of this study was to compare the prevalence of positive DXA-based indicators for bone health deficits in children with CP to the prevalence of positive findings after applying a functional muscle-bone unit diagnostic algorithm (FMBU-A) considering reduced muscle activity. METHODS: The present study was a monocentric retrospective analysis of 297 whole body DXA scans of children with CP. The prevalence of positive results of age- and height-adjusted BMC and aBMD defined as BMC and aBMD below the P3 percentile and of the FMBU-A was calculated. RESULTS: In children with CP, the prevalence of positive results of age-adjusted BMC were 33.3% and of aBMD 50.8%. Height-adjusted results for BMC and aBMD were positive in 16.8 and 36.0% of cases. The prevalence of positive results applying the FMBU-A regarding BMC and aBMD were significantly (p < 0.001) lower than using age- and height-adjusted BMC and aBMD (8.8 and 14.8%). CONCLUSIONS: Our results suggest that the prevalence of bone health deficits in children with CP was overestimated, when using age- and height-adjusted BMC and aBMD. When applying the FMBU-A, the prevalence decreased significantly. We recommend applying the FMBU-A when assessing bone health in children with CP.

来源:Osteoporos Int,查看原文。版权归原作者所有。

引用

  1. Duran I, Schütz F, Hamacher S, et al. The functional muscle-bone unit in children with cerebral palsy. Osteoporos Int. 2017. PMID: 28365851. doi:10.1007/s00198-017-4023-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。