文献速递运动医学关节外科

高分辨率磁共振成像所显示的前交叉韧带蝴蝶结形态

The Bow Tie Shape of the Anterior Cruciate Ligament as Visualized by High-Resolution Magnetic Resonance Imaging.
PubMed 文献 · Am J Sports Med · 2017-04-21

本研究为描述性实验室研究,纳入96例3.0-T磁共振成像,通过三维曲面多平面重建在7个点测量前交叉韧带横截面的宽度和厚度,并生成平均模型。结果显示前交叉韧带呈蝴蝶结形态,包括椭圆形的峡部、半圆形的股骨止点和肾豆形的胫骨止点。作者认为该测量方法可使外科医生在真实患者中无创定量诊断前交叉韧带部分损伤。

要点

  • 前交叉韧带在3.0-T磁共振成像上呈蝴蝶结形态,包括椭圆形峡部、半圆形股骨止点和肾豆形胫骨止点。
  • 股骨止点和胫骨止点的宽度和厚度均显著大于中段4,差异有统计学意义(P < .001)。
  • 作者认为该测量方法可使外科医生在真实患者中无创定量诊断前交叉韧带部分损伤。

核心结论

  • 在3.0-T磁共振成像上,前交叉韧带呈「蝴蝶结」形态,包括椭圆形峡部、半圆形股骨止点和肾豆形胫骨止点。

研究设计与样本

  • 描述性实验室研究,纳入96例使用3.0-T磁共振设备进行的磁共振成像,分析前交叉韧带形态。
  • 采用三维曲面多平面重建在7个点获取横截面:股骨止点、中段1至5(从股骨侧到胫骨侧)、胫骨止点。
  • 由2名独立观察者测量横截面宽度和厚度,计算宽度与厚度比值以确定各横截面比例,并累积标准化7个横截面以生成平均模型。

主要发现

  • 股骨止点宽度17.02 ± 2.17 mm、厚度11.03 ± 1.75 mm,胫骨止点宽度17.33 ± 2.03 mm、厚度10.09 ± 1.70 mm,两处止点的宽度和厚度均显著大于中段4(宽度9.99 ± 1.87 mm、厚度6.53 ± 1.25 mm),P < .001。
  • 从股骨止点到胫骨止点7个横截面的宽度与厚度比值分别为1.57 ± 0.23、3.36 ± 0.57、3.07 ± 0.81、2.18 ± 0.54、1.56 ± 0.32、2.16 ± 0.48、1.75 ± 0.28。
  • 中段4横截面形状为椭圆形峡部,是最窄且最均衡的形状,在中段1和中段5转变为宽带状。
  • 股骨止点形状为半圆形,其前侧略直、后侧凸出;胫骨止点为肾豆形。

临床怎么用

  • 作者认为,该测量方法将使外科医生能够在真实患者中使用无创系统定量诊断前交叉韧带部分损伤。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although numerous studies have examined the anatomic characteristics of the anterior cruciate ligament (ACL), its actual shape remains unclear. PURPOSE: To determine the average shape of the ACL by analyzing its cross section through the use of high-resolution magnetic resonance imaging (MRI) data. STUDY DESIGN: Descriptive laboratory study. METHODS: The study included 96 MRIs, conducted using a 3.0-T magnet, to analyze the shape of the ACL. Three-dimensional, curved multiplanar reconstruction was used to obtain cross sections at 7 points (femoral insertion; midsubstance 1, 2, 3, 4, and 5 from the femoral side to the tibial side; and tibial insertion). The width and thickness of cross sections were measured by 2 independent observers, and the ratio of width to thickness was calculated to determine the proportions of each cross section. The 7 cross sections were accumulated and standardized to generate an average model through the use of image analysis software developed by the authors. RESULTS: The mean ± SD width (femoral insertion, 17.02 ± 2.17 mm; tibial insertion, 17.33 ± 2.03 mm) and thickness (femoral insertion, 11.03 ± 1.75 mm; tibial insertion, 10.09 ± 1.70 mm) of both insertions were significantly larger than those of midsubstance 4 (width, 9.99 ± 1.87 mm; thickness, 6.53 ± 1.25 mm) ( P < .001). The mean ratios of width to thickness of the 7 cross sections from femoral insertion to tibial insertion were 1.57 ± 0.23, 3.36 ± 0.57, 3.07 ± 0.81, 2.18 ± 0.54, 1.56 ± 0.32, 2.16 ± 0.48, and 1.75 ± 0.28, respectively. The shape of the cross section at midsubstance 4 was an oval isthmus, which was the most narrow and well-balanced shape. It was transformed into a wide band at midsubstance 1 and 5. The shape of the femoral insertion was semicircular, with its anterior side slightly straight and its posterior side convex. The tibial insertion was kidney bean-shaped. CONCLUSION: On 3.0-T MRI, the ACL has a "bow tie" shape, including an oval isthmus, with a semicircular femoral insertion and kidney bean-shaped tibial insertion. CLINICAL RELEVANCE: The measurement method will allow surgeons to quantitatively diagnose partial injuries of the ACL using a noninvasive system in actual patients.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Sohn KM, Lee MJ, Hong H, et al. The Bow Tie Shape of the Anterior Cruciate Ligament as Visualized by High-Resolution Magnetic Resonance Imaging. Am J Sports Med. 2017. PMID: 28430526. doi:10.1177/0363546517699828

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。