当代锥形配合保留骨量短柄股骨假体全髋关节置换术的早期基于表现和患者报告结局
前瞻性分析33例使用近端多孔涂层锥形短柄股骨假体和53例使用常规长度非骨水泥股骨假体的全髋关节置换术患者,至少随访两年,平均随访31.4个月。两组术后牛津髋关节评分、EuroQol 5D和University College Hospital髋关节评分功能亚组均无差异,术前评分均显著改善(所有p < 0.001)。作者认为在骨质量好的患者中,短柄假体获得与常规长柄非骨水泥假体相当的短期功能结局。
要点
- 短柄组与常规柄组术后牛津髋关节评分、EuroQol 5D和University College Hospital髋关节评分功能亚组均无差异。
- 短柄组和常规柄组University College Hospital髋关节评分功能成分末次随访均值分别为42.5和40.6(p = 0.42)。
- 短柄组7例(21.2%)、常规柄组9例(16.98%)在牛津髋关节评分出现天花板效应,功能亚组均无天花板效应。
核心结论
- 在骨质量好的患者中行全髋关节置换术时,近端多孔涂层锥形短柄股骨假体与常规较长非骨水泥股骨假体相比获得相当的短期功能结局。
研究设计与样本
- 前瞻性分析33例使用当代近端多孔涂层锥形短柄股骨假体和53例使用标准常规股骨假体的全髋关节置换术患者,至少随访两年,平均随访31.4个月(24至39)。
- 排除近端股骨骨质量差的患者;患者平均年龄66.6岁(59至77),平均体重指数30.2 kg/m2(24.1至41.0)。
主要发现
- 无重大围手术期并发症。
- 两组术后平均牛津髋关节评分、EuroQol 5D或University College Hospital髋关节评分功能亚组均无差异。
- 术前平均牛津髋关节评分和EuroQol 5D评分显著改善(所有p < 0.001)。
- 末次随访时University College Hospital髋关节评分功能成分均值在短柄组和常规柄组分别为42.5和40.6,组间差异无统计学显著(p = 0.42)。
- 短柄组7例(21.2%)和常规柄组9例(16.98%)在牛津髋关节评分达到天花板效应;功能亚组均无天花板效应。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of this study was to compare early functional and health related quality of life outcomes (HRQoL) in patients who have undergone total hip arthroplasty (THA) using a bone conserving short stem femoral component and those in whom a conventional length uncemented component was used. Outcome was assessed using a validated performance based outcome instrument as well as patient reported outcome measures (PROMs). PATIENTS AND METHODS: We prospectively analysed 33 patients whose THA involved a contemporary proximally porous coated tapered short stem femoral component and 53 patients with a standard conventional femoral component, at a minimum follow-up of two years. The mean follow-up was 31.4 months (24 to 39). Patients with poor proximal femoral bone quality were excluded. The mean age of the patients was 66.6 years (59 to 77) and the mean body mass index was 30.2 kg/m2 (24.1 to 41.0). Outcome was assessed using the Oxford Hip Score (OHS) and the University College Hospital (UCH) hip score which is a validated performance based instrument. HRQoL was assessed using the EuroQol 5D (EQ-5D). RESULTS: There were no major peri-operative complications. There was no difference in the mean post-operative OHS, EQ-5D or function subscale of the UCH hip scores between the two groups. The mean pre-operative OHS and EQ-5D scores improved significantly (all p < 0.001). The mean functional component of the UCH hip score at final follow-up was 42.5 and 40.6 in the short stem and conventional stem groups, respectively. There was no statistically significant difference between the groups (p = 0.42). A total of seven patients (21.2%) in the short stem group and nine (16.98%) in the conventional group achieved a ceiling effect using the OHS; none did using the function subscale of the UCH hip score. CONCLUSION: The proximally porous coated tapered short stem femoral component achieves comparable short-term functional outcomes when compared with a conventional longer stem uncemented femoral component when THA is undertaken in patients with good bone quality. Cite this article: Bone Joint J 2017;99-B(4 Supple B):49-55.
引用
- Hossain F, Konan S, Volpin A, et al. Early performance-based and patient-reported outcomes of a contemporary taper fit bone-conserving short stem femoral component in total hip arthroplasty. Bone Joint J. 2017. PMID: 28363894. doi:10.1302/0301-620X.99B4.BJJ-2016-1291.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。