股骨柄骨水泥套内翻修:瑞典髋关节置换登记系统1179例首次翻修分析
基于瑞典髋关节置换登记系统1999年1月至2015年12月1179例使用Exeter或Lubinus柄的骨水泥套内翻修,Kaplan-Meier生存分析显示6年假体生存率Exeter组91%(标准差2.8%)优于Lubinus组85%(标准差5.0%)(p=0.02),但柄生存率及再翻修风险无显著差异。
要点
- 骨水泥套内翻修6年假体生存率Exeter组91%优于Lubinus组85%(p=0.02)。
- 柄生存率Exeter组94%、Lubinus组95%,两组间无显著差异(p=0.58)。
- 无菌性松动再翻修风险两组无显著差异(p=0.97)。
核心结论
- 骨水泥套内翻修技术使用Exeter和Lubinus两种柄设计在术后6年均获得有希望的结果。
研究设计与样本
- 基于瑞典髋关节置换登记系统(SHAR)1999年1月至2015年12月1179例Exeter或Lubinus柄骨水泥套内翻修的登记分析,采用Kaplan-Meier生存分析。
主要发现
- 6年假体生存率Exeter组91%(标准差2.8%)优于Lubinus组85%(标准差5.0%)(p=0.02)。
- 柄生存率Exeter组94%(标准差2.2%)与Lubinus组95%(标准差3.2%)无显著差异(p=0.58)。
- 无菌性松动再翻修风险Exeter组98%(标准差1.6%)与Lubinus组98%(标准差2.2%)无显著差异(p=0.97)。
- 数据库无法识别进一步翻修是因髋臼侧还是股骨侧假体松动或两者兼有。
临床怎么用
- 原文结论未据此给出临床推荐。
局限性
- 数据库无法识别进一步翻修是因髋臼侧还是股骨侧假体松动或两者兼有。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Compared with primary total hip arthroplasty (THA), revision surgery can be challenging. The cement-in-cement femoral revision technique involves removing a femoral component from a well-fixed femoral cement mantle and cementing a new stem into the original mantle. This technique is widely used and when carried out for the correct indications, is fast, relatively inexpensive and carries a reduced short-term risk for the patient compared with the alternative of removing well-fixed cement. We report the outcomes of this procedure when two commonly used femoral stems are used. PATIENTS AND METHODS: We identified 1179 cement-in-cement stem revisions involving an Exeter or a Lubinus stem reported to the Swedish Hip Arthroplasty Register (SHAR) between January 1999 and December 2015. Kaplan-Meier survival analysis was performed. RESULTS: Survivorship is reported up to six years and was better in the Exeter group (91% standard deviation (sd) 2.8% versus 85% sd 5.0%) (p = 0.02). There was, however, no significant difference in the survival of the stem and risk of re-revision for any reason (p = 0.58) and for aseptic loosening (p = 0.97), between revisions in which the Exeter stem (94% sd 2.2%; 98% sd 1.6%) was used compared with those in which the Lubinus stem (95% sd 3.2%; 98% sd 2.2%) was used. The database did not allow identification of whether a further revision was indicated for loosening of the acetabular or femoral component or both. CONCLUSION: The cement-in-cement technique for revision of the femoral component gave promising results using both designs of stem, six years post-operatively. Cite this article: Bone Joint J 2017;99-B(4 Supple B):27-32.
引用
- Cnudde PH, Kärrholm J, Rolfson O, et al. Cement-in-cement revision of the femoral stem: analysis of 1179 first-time revisions in the Swedish Hip Arthroplasty Register. Bone Joint J. 2017. PMID: 28363891. doi:10.1302/0301-620X.99B4.BJJ-2016-1222.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。