重建笼与多孔金属增块治疗髋翻修术中巨大髋臼骨缺损
研究纳入19例患者共22个髋臼翻修,采用重建笼联合多孔金属增块替代结构植骨,所有患者髋臼节段性缺损超过50%,其中7髋合并骨盆不连续。平均随访39个月,3例失败均发生于2髋既往因髋臼肿瘤行切除的患者;牛津髋关节评分从13.9显著升至28.7(p<0.00001)。作者结论认为早期生存率可接受,但该技术可能不适用于既往因髋臼肿瘤行切除的患者。
要点
- 22个髋臼翻修采用重建笼联合多孔金属增块,平均随访39个月。
- 3例失败均见于2髋既往因髋臼肿瘤行切除的患者。
- 牛津髋关节评分从13.9升至28.7(p<0.00001)。
核心结论
- 采用重建笼联合多孔金属增块可获得可接受的早期生存率,但该技术可能不适用于既往因髋臼肿瘤行切除的患者。
研究设计与样本
- 共22个髋臼翻修(19例患者),采用重建笼联合多孔金属增块,增块替代结构植骨。
- 手术时平均年龄70岁(27至85),平均随访39个月(27至58),既往全髋关节置换平均1.9次(1至3)。
- 所有患者髋臼节段性缺损超过50%,其中7髋合并骨盆不连续。
主要发现
- 2髋共出现3例失败,两髋均既往因髋臼肿瘤行切除。
- 其他并发症包括迟发动脉损伤、坐骨神经麻痹、脱位行股骨翻修、深部感染行冲洗清创、大转子骨折保守治疗。
- 牛津髋关节评分均值从13.9(2至23)显著升至28.7(13至38)(p<0.00001)。
- 髋旋转中心与正常位置的平均垂直距离从30 mm降至10 mm。
临床怎么用
- 作者认为,该技术可获得可接受的早期生存率,但可能不适用于既往因髋臼肿瘤行切除的患者。
局限性
- 该技术可能不适用于既往因髋臼肿瘤行切除的患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: It may not be possible to undertake revision total hip arthroplasty (THA) in the presence of massive loss of acetabular bone stock using standard cementless hemispherical acetabular components and metal augments, as satisfactory stability cannot always be achieved. We aimed to study the outcome using a reconstruction cage and a porous metal augment in these patients. PATIENTS AND METHODS: A total of 22 acetabular revisions in 19 patients were performed using a combination of a reconstruction cage and porous metal augments. The augments were used in place of structural allografts. The mean age of the patients at the time of surgery was 70 years (27 to 85) and the mean follow-up was 39 months (27 to 58). The mean number of previous THAs was 1.9 (1 to 3). All patients had segmental defects involving more than 50% of the acetabulum and seven hips had an associated pelvic discontinuity. RESULTS: Three failures were observed in two hips, both of which had undergone a previous resection of a tumour affecting the acetabulum. Other complications included a late arterial injury, a sciatic nerve palsy, a dislocation treated with a femoral revision, a deep infection treated with irrigation and debridement and a fracture of the greater trochanter treated conservatively. The mean Oxford Hip Score significantly increased from 13.9 (2 to 23) to 28.7 (13 to 38) (p < 0.00001). The mean vertical distance between the centre of rotation of the hip and its normal location decreased from 30 mm to 10 mm. CONCLUSIONS: Acceptable early survivorship can be achieved using this novel technique, but it may be unsuitable for use in patients who have previously undergone the resection of a tumour involving the acetabulum. Cite this article: Bone Joint J 2017;99-B:607-13.
引用
- Mäkinen TJ, Abolghasemian M, Watts E, et al. Management of massive acetabular bone defects in revision arthroplasty of the hip using a reconstruction cage and porous metal augment. Bone Joint J. 2017. PMID: 28455469. doi:10.1302/0301-620X.99B5.BJJ-2014-0264.R3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。