文献速递关节外科

维生素E扩散高交联聚乙烯在全髋关节置换术中五年随访:一项使用放射立体分析法的随机对照试验

Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis.
PubMed 文献 · Bone Joint J · 2017-01-01

这项为期五年的前瞻性盲法随机对照试验比较了维生素E扩散高交联聚乙烯(HXLPE)内衬与中等交联聚乙烯对照内衬的股骨头穿透情况。E1组32例,ArComXL组35例,中位年龄66岁(40至76岁)。五年时E1组中位近端股骨头穿透为-0.05 mm,ArComXL组为0.07 mm;第3年和第5年ArComXL组穿透显著大于E1组(p=0.029和p=0.019)。两组患者报告结局均较术前显著改善并维持至五年,组间无差异。

要点

  • 五年时E1组中位近端股骨头穿透为-0.05 mm(四分位距-0.13至-0.02),ArComXL组为0.07 mm(-0.03至0.16)。
  • 第3年和第5年ArComXL组穿透显著大于E1组(p=0.029和p=0.019)。
  • 两组患者报告结局均较术前显著改善并维持至五年,组间各时间点无差异。

核心结论

  • 五年结果显示E1聚乙烯的磨损不大于对照ArComXL。
  • 这是比较维生素E扩散HXLPE与上一代中等交联聚乙烯磨损性能和临床结局的最长期随机对照试验。

研究设计与样本

  • 为期五年的前瞻性、盲法、随机对照试验(RCT)。
  • 计划行全髋关节置换术的患者随机接受研究用E1聚乙烯(32例)或对照ArComXL聚乙烯(35例)。
  • 总体队列中位年龄66岁(范围40至76岁)。
  • 使用放射立体分析法(RSA)评估股骨头穿透。

主要发现

  • 五年中位(四分位距)近端股骨头穿透:E1组-0.05 mm(-0.13至-0.02),ArComXL组0.07 mm(-0.03至0.16)。
  • 第3年和第5年ArComXL组穿透显著大于E1组(p=0.029和p=0.019)。
  • 所有患者报告结局(PROs)较术前显著改善并维持至五年,两组各时间点无差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The objective of this five-year prospective, blinded, randomised controlled trial (RCT) was to compare femoral head penetration into a vitamin E diffused highly cross-linked polyethylene (HXLPE) liner with penetration into a medium cross-linked polyethylene control liner using radiostereometric analysis. PATIENTS AND METHODS: Patients scheduled for total hip arthroplasty (THA) were randomised to receive either the study E1 (32 patients) or the control ArComXL polyethylene (35 patients). The median age (range) of the overall cohort was 66 years (40 to 76). RESULTS: The five-year median (interquartile range) proximal femoral head penetration into the E1 was -0.05 mm (-0.13 to -0.02) and 0.07 mm (-0.03 to 0.16) for ArComXL. At three and five years, the penetration was significantly greater in the ArComXL group compared with the E1 group (p = 0.029 and p = 0.019, respectively). All patient-reported outcomes (PROs) improved significantly from the pre-operative interval compared with those at one year, and remained favourable at five years. There were no differences between the two groups at any interval. CONCLUSION: The five-year results showed that E1 polyethylene does not wear more than the control, ArComXL. This is the longest-term RCT comparing the wear performance and clinical outcome of vitamin E diffused HXLPE with a previous generation of medium cross-linked polyethylene. Cite this article: Bone Joint J 2017;99-B:577-84.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Nebergall AK, Greene ME, Laursen MB, et al. Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years: a randomised controlled trial using radiostereometric analysis. Bone Joint J. 2017. PMID: 28455465. doi:10.1302/0301-620X.99B5.37521

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。