文献速递关节外科

无症状陶瓷-聚乙烯全髋关节置换患者金属伪影减少序列MRI异常

Metal Artifact Reduction Sequence MRI Abnormalities in Asymptomatic Patients with a Ceramic-on-Polyethylene Total Hip Replacement.
PubMed 文献 · J Bone Joint Surg Am · 2017-01-01

本研究纳入44例(50髋)无症状陶瓷-聚乙烯全髋关节置换患者,随访至少2年且Harris髋关节评分>90,行金属伪影减少序列MRI检查。9髋(18%)发现液体积聚,其中5髋为关节囊内滑膜炎(2髋滑膜增厚),另4髋为与关节囊内直接相通的关节外液体积聚(2髋滑膜增厚)。作者结论认为液体积聚并不少见,滑膜增厚可能比既往金属-聚乙烯假体研究报道更常见,其临床意义和自然史尚不明确。

要点

  • 无症状陶瓷-聚乙烯全髋关节置换患者中,9/50髋(18%)MARS MRI发现液体积聚。
  • 5髋为关节囊内滑膜炎,其中2髋滑膜增厚;4髋为与关节囊内相通的关节外液体积聚,其中2髋滑膜增厚。
  • 作者认为滑膜增厚可能比既往金属-聚乙烯假体研究报道更常见,但临床意义和自然史尚不明确。

核心结论

  • 作者结论认为,陶瓷-聚乙烯全髋关节置换术后液体积聚并不少见,滑膜增厚可能存在且比既往金属-聚乙烯假体研究报道更常见,这些发现的临床意义和自然史尚不明确。

研究设计与样本

  • 本研究纳入44例(50髋)陶瓷-聚乙烯全髋关节置换术后至少2年、Harris髋关节评分>90的无症状患者,纳入标准为无髋部疼痛且具备合适随访X线片,所有患者接受金属伪影减少序列MRI检查以确定液体积聚。

主要发现

  • 50髋无症状髋中9髋(18%)观察到液体积聚。
  • 5髋为关节囊内滑膜炎,其中2髋滑膜增厚。
  • 另4髋为与关节囊内直接相通的关节外液体积聚,其中2髋滑膜增厚。
  • 最近随访X线片未见骨溶解征象或不良局部组织反应证据。

关键数值与推荐

  • 无症状陶瓷-聚乙烯全髋关节置换患者中,MARS MRI显示液体积聚9/50髋(18%)。
  • 关节囊内滑膜炎5髋,其中滑膜增厚2髋;关节外液体积聚4髋,其中滑膜增厚2髋。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者指出这些发现的临床意义和自然史尚不明确。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Magnetic resonance imaging (MRI) is a commonly utilized screening modality in patients with a metal-on-metal (MoM) total hip replacement. The prevalence of clinically important fluid collections may be overestimated since these collections have been reported to occur in asymptomatic patients with MoM and other bearing surfaces. The purpose of this study was to determine the frequency and types of MRI-documented adverse local tissue reactions in asymptomatic patients with a ceramic-on-polyethylene (CoP) total hip replacement. METHODS: Forty-four patients (50 hips) with a minimum 2-year follow-up after total hip arthroplasty with CoP implants and a Harris hip score of >90 were enrolled in this study. The inclusion criteria were the absence of hip pain and the availability of appropriate follow-up radiographs. All patients underwent a metal artifact reduction sequence (MARS) MRI scan to determine the presence of fluid collections in asymptomatic patients with a CoP bearing surface. RESULTS: Fluid collections were observed in 9 (18%) of 50 asymptomatic hips in this cohort. There were 5 hips with intracapsular synovitis, and 2 of these hips had a thickened synovium. Extra-articular fluid collections with direct intracapsular communication were identified in 4 additional hips. Two of these hips had a thickened synovium. No signs of osteolysis or evidence of adverse local tissue reactions were noted on radiographs at the most recent follow-up. CONCLUSIONS: This study revealed that fluid collections are not uncommon after total hip arthroplasty with CoP implants. Synovial thickening may be present and is more prevalent than has been reported in previous studies involving metal-on-polyethylene (MoP) bearing surfaces. The clinical importance and natural history of these findings remain unknown. LEVEL OF EVIDENCE: Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Jennings JM, Martin JR, Kim RH, et al. Metal Artifact Reduction Sequence MRI Abnormalities in Asymptomatic Patients with a Ceramic-on-Polyethylene Total Hip Replacement. J Bone Joint Surg Am. 2017. PMID: 28375892. doi:10.2106/JBJS.16.00910

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。