研究基于假体失败机制和DeLee及Charnley分区骨溶解位置开发了总分10分的影像学评分系统,回顾96例因磨损或骨溶解行翻修术的术前X线片,术中确认64个假体固定良好、32个松动,两组平均总分分别为2.9分和7.2分(p<0.001),评分≥5分时诊断松动的敏感性0.79、特异性0.87,曲线下面积0.90。

要点

  • 评分系统按DeLee及Charnley三区分别计分,总分最高10分,评分越高松动概率越大。
  • 术中确认固定良好组平均总分2.9分,松动组7.2分,差异有统计学意义(p<0.001)。
  • 评分≥5分诊断松动的敏感性0.79、特异性0.87,曲线下面积0.90(p<0.001)。

核心结论

  • 评分系统与骨溶解情况下非骨水泥髋臼假体松动概率呈强相关,可为术前计划和翻修手术结局评估提供临床有用的工具。

研究设计与样本

  • 研究纳入2002年7月至2012年12月间91例患者因磨损或骨溶解行96次翻修术,回顾术前骨盆正位X线片和Judet位片,以术中确认的假体稳定性为参考标准。
  • 评分系统基于假体失败机制和按DeLee及Charnley分区的骨溶解病灶位置,每区单独评分,三区之和为总分,最高10分。

主要发现

  • 术中确认64个假体固定良好、32个松动。
  • 固定良好组平均总分2.9分(范围0至7),松动组平均总分7.2分(范围1至10),p<0.001。
  • 评分0至2分的33髋中仅1髋(3%)松动;评分3至4分的19个假体中2个(10.5%)松动;评分5至6分的19髋中8个(44.5%)松动;评分7至8分的17个假体中13个(70.6%)松动;评分9至10分的9髋中9个(100%)松动。
  • 受试者工作特征曲线分析示曲线下面积0.90(p<0.001),最佳截断点为评分≥5分,敏感性0.79、特异性0.87。

关键数值与推荐

  • 总分最高10分,按DeLee及Charnley三区分别评分后相加。
  • 评分≥5分作为诊断松动的截断点,敏感性0.79、特异性0.87,曲线下面积0.90(p<0.001)。

临床怎么用

  • 原文结论认为该评分系统可为骨溶解情况下非骨水泥髋臼假体松动的术前计划和翻修手术结局评估提供临床有用的工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The stability of cementless acetabular components is an important factor for surgical planning in the treatment of patients with pelvic osteolysis after total hip arthroplasty (THA). However, the methods for determining the stability of the acetabular component from pre-operative radiographs remain controversial. Our aim was to develop a scoring system to help in the assessment of the stability of the acetabular component under these circumstances. PATIENTS AND METHODS: The new scoring system is based on the mechanism of failure of these components and the location of the osteolytic lesion, according to the DeLee and Charnley classification. Each zone is evaluated and scored separately. The sum of the individual scores from the three zones is reported as a total score with a maximum of 10 points. The study involved 96 revision procedures which were undertaken for wear or osteolysis in 91 patients between July 2002 and December 2012. Pre-operative anteroposterior pelvic radiographs and Judet views were reviewed. The stability of the acetabular component was confirmed intra-operatively. RESULTS: Intra-operatively, it was found that 64 components were well-fixed and 32 were loose. Mean total scores in the well-fixed and loose components were 2.9 (0 to 7) and 7.2 (1 to 10), respectively (p < 0.001). In hips with a low score (0 to 2), the component was only loose in one of 33 hips (3%). The incidence of loosening increased with increasing scores: in those with scores of 3 and 4, two of 19 components (10.5%) were loose; in hips with scores of 5 and 6, eight of 19 components (44.5%) were loose; in hips with scores of 7 or 8, 13 of 17 components (70.6%) were loose; and for hips with scores of 9 and 10, nine of nine components (100%) were loose. Receiver-operating-characteristic curve analysis demonstrated very good accuracy (area under the curve = 0.90, p < 0.001). The optimal cutoff point was a score of ≥ 5 with a sensitivity of 0.79, and a specificity of 0.87. CONCLUSION: There was a strong correlation between the scoring system and the probability of loosening of a cementless acetabular component. This scoring system provides a clinically useful tool for pre-operative planning, and the evaluation of the outcome of revision surgery for patients with loosening of a cementless acetabular component in the presence of osteolysis. Cite this article: Bone Joint J 2017;99-B:601-6.