文献速递关节外科

Marathon高交联聚乙烯在全髋关节置换术中的10年随访磨损分析

10-Year Follow-Up Wear Analysis of Marathon Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-03-23

研究回顾35例使用特定高交联聚乙烯内衬的全髋关节置换术,平均随访10年,平均磨损率为0.07毫米/年,总磨损0.71毫米,无骨溶解,以全因翻修为终点的生存率为100%。结论认为高交联聚乙烯内衬的磨损率持续低于传统聚乙烯的已发表数据。

要点

  • 平均随访10年(118个月,范围7.2-13.4年),平均磨损率0.07毫米/年,总磨损0.71毫米。
  • 所有髋关节任何区域均无骨溶解证据。
  • 以全因翻修为终点的生存率为100%。

核心结论

  • 高交联聚乙烯内衬的磨损率持续低于传统聚乙烯的已发表磨损率,并再次确认高交联聚乙烯髋臼内衬在初次全髋关节置换术中具有可接受的低磨损率。

研究设计与样本

  • 回顾性分析35例使用特定高交联聚乙烯内衬的初次全髋关节置换术,通过前后位X线片评估股骨头穿透、骨溶解、长期生存率、总磨损和磨损率。

主要发现

  • 手术时平均年龄70岁,平均随访10年(118个月,范围7.2-13.4年)。
  • 本队列平均磨损率为0.07毫米/年,研究期间总磨损为0.71毫米。
  • 所有髋关节任何区域均无骨溶解证据。
  • 以全因翻修为终点的最新随访生存率为100%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Short-term and intermediate-term wear rates for highly cross-linked polyethylene (HCLPE) liners in total hip arthroplasty (THA) are significantly lower than published rates for traditional polyethylene liners. The aim of this study was to report the longest-to-date follow-up of a specific HCLPE liner. METHODS: A series of 35 THAs using a specific HCLPE liner were reviewed. Anteroposterior radiographs were reviewed for femoral head penetration, the presence of femoral and/or acetabular osteolysis, long-term survival, total wear, and wear rates in all patients. RESULTS: The average patient age at time of surgery was 70 years with an average follow-up of 10 years (118 months; range, 7.2-13.4 years). The mean wear rate in our cohort was 0.07 mm/y. Total wear was 0.71 mm over the study period. No hips showed evidence of osteolysis in any zones. Survivorship at latest follow-up was 100% with all-cause revision as an end point. CONCLUSION: The wear rate of HCLPE liners continues to be lower than published wear rates for traditional polyethylene and continues to reaffirm the acceptably low wear rates using HCLPE acetabular liner in primary THA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Bookman JS, Kaye ID, Chen KK, et al. 10-Year Follow-Up Wear Analysis of Marathon Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 28438454. doi:10.1016/j.arth.2017.03.016