文献速递关节外科创伤骨科

假体周围温哥华B1型骨折骨接合失败后采用非骨水泥模块化锥形翻修柄行髋关节翻修术

Hip revision arthroplasty for failed osteosynthesis in periprosthetic Vancouver type B1 fractures using a cementless, modular, tapered revision stem.
PubMed 文献 · Bone Joint J · 2017-01-01

本研究纳入14例假体周围温哥华B1型骨折骨接合失败患者,采用经股骨入路移除固定良好的假体柄,置入非骨水泥模块化锥形翻修柄行髋关节翻修术。平均随访52.2个月,所有骨折平均15.5周愈合,无柄下沉,Harris髋关节评分从术前22.2分升至术后24个月81.5分。作者认为该技术可重复地获得良好结果。

要点

  • 14例温哥华B1型骨折骨接合失败患者采用经股骨入路非骨水泥模块化锥形翻修柄行翻修术。
  • 所有骨折平均15.5周(标准差5.7)愈合,无柄下沉,均获骨长入固定。
  • Harris髋关节评分从术前22.2分升至术后24个月81.5分,所有髋按Beals和Tower分类获优。

核心结论

  • 作者认为所描述的翻修柄技术治疗假体周围温哥华B1型骨折骨接合失败可重复地获得良好结果。

研究设计与样本

  • 本研究为病例系列,共纳入14例(11例女性、3例男性)平均年龄72.4岁(65至90岁)的假体周围温哥华B1型骨折骨接合失败后行髋关节翻修术患者。
  • 手术采用经股骨入路移除固定良好的假体柄,随后置入获得远端固定的模块化带凹槽钛制翻修柄。
  • 患者接受平均52.2个月(24至144个月)的临床和影像学随访。

主要发现

  • 所有骨折在平均15.5周(标准差5.7)内愈合。
  • 无假体柄下沉,根据Engh等的分类均发生骨长入固定。
  • 平均Harris髋关节评分从术前22.2分(标准差9.7)提高至术后24个月81.5分(标准差16.8)。
  • 根据Beals和Tower分类,所有髋均获得优的结果。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: To evaluate the hypothesis that failed osteosynthesis of periprosthetic Vancouver type B1 fractures can be treated successfully with stem revision using a transfemoral approach and a cementless, modular, tapered revision stem with reproducible rates of fracture healing, stability of the revision stem, and clinically good results. PATIENTS AND METHODS: A total of 14 patients (11 women, three men) with a mean age of 72.4 years (65 to 90) undergoing revision hip arthroplasty after failed osteosynthesis of periprosthetic fractures of Vancouver type B1 were treated using a transfemoral approach to remove the well-fixed stem before insertion of a modular, fluted titanium stem which obtained distal fixation. These patients were clinically and radiologically followed up for a mean 52.2 months (24 to 144). RESULTS: After a mean of 15.5 weeks (standard deviation (sd) 5.7) all fractures had healed. No stems subsided and bony-ingrowth fixation had occurred according to the classification of Engh et al. The mean Harris Hip Score increased from a pre-operative score of 22.2 points (sd 9.7) to 81.5 points (sd 16.8) 24 months post-operatively. All hips had obtained an excellent result according to the classification of Beals and Tower. CONCLUSIONS: The technique described here for stem revision provides reproducibly good results in the treatment of failed osteosynthesis for Vancouver types B1 periprosthetic fractures of the hip. Cite this article: Bone Joint J 2017;99-B(4 Supple B):11-16.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Fink B, Oremek D. Hip revision arthroplasty for failed osteosynthesis in periprosthetic Vancouver type B1 fractures using a cementless, modular, tapered revision stem. Bone Joint J. 2017. PMID: 28363889. doi:10.1302/0301-620X.99B4.BJJ-2016-1201.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。