文献速递关节外科

全膝关节翻修术中伸膝装置的评估

Evaluation of Extensor Mechanism in Revision Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-03-22

该回顾性研究比较了V-Y股四头肌成形术(QP)与股四头肌剪开术(QS)在92例全膝关节翻修术中的结果,随访12至108个月;两组在伸膝受限、内外翻畸形、膝关节屈曲角度、屈伸肌力及HSS和LEFS评分上均无统计学显著差异(P > .05);作者认为QP可为僵硬膝和翻修手术提供更宽的关节切开和更大的关节显露,且不带来伸膝装置方面的劣势。

要点

  • QP组55膝与QS组37膝在伸膝受限、内外翻畸形及屈膝角度上无显著差异(P > .05)。
  • 两组HSS评分和LEFS评分无统计学显著差异(P > .05)。
  • 作者认为QP允许更宽关节切开和更大关节显露,不带来伸膝装置劣势。

核心结论

  • QP是僵硬膝和翻修膝关节手术中可优先选择的方法,能提供更宽的关节切开和更大的关节显露,选择该切口不带来伸膝装置方面的劣势。

研究设计与样本

  • 回顾性研究,纳入92例全膝关节翻修术后的膝关节,随访12至108个月,其中采用QP者55膝、采用QS者37膝。

主要发现

  • 伸膝受限、内外翻畸形、膝关节屈曲角度、屈伸肌力、HSS评分和LEFS评分在QP与QS两组间均无统计学显著差异(P > .05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The success of revision total knee arthroplasty depends on adequate exposure that does not produce complications. The purpose of this study was to compare the results of revision total knee arthroplasty between V-Y quadricepsplasty (QP) and quadriceps snip (QS) approaches. METHODS: In the study, 92 knees with follow-up of 12-108 months which were operated by using QP (55) and QS (37) were evaluated retrospectively. Measurements were taken by using universal transparent goniometer, also varus valgus deformities, knee flexion angles, instability, Hospital for Special Surgery and Lower Extremity Functional Scale scores, functional condition of the knee and activity levels of the patients were evaluated cross-sectionally. RESULTS: Statistically significant difference was not found regarding extensor restriction, varus or valgus deformities, knee flexion angles, flexor and extensor muscular strength, Hospital for Special Surgery and Lower Extremity Functional Scale score (P > .05). CONCLUSION: QP is a preferable method which allows a wider arthrotomy for stiff knees and revision knee surgery, and provides larger access to the joint. Choosing this incision does not bring disadvantage in terms of extensor mechanism.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Zhamilov V, Karatosun V, Kalkan S, et al. Evaluation of Extensor Mechanism in Revision Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28413139. doi:10.1016/j.arth.2017.03.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。