文献速递关节外科

使用一体式非骨水泥股骨柄对儿童期Perthes病患者行全髋关节置换术

Total hip arthroplasty using a monobloc cementless femoral stem for patients with childhood Perthes' disease.
PubMed 文献 · Bone Joint J · 2017-01-01

回顾性分析68例儿童期Perthes病行全髋关节置换术的患者,使用一体式非骨水泥股骨柄,平均随访8.5年,术中股骨距骨折8髋(11.8%)经环扎钢丝成功处理,无脱位、无翻修,末次随访Harris髋关节评分平均91分,结论为一体式非骨水泥柄可可靠重建解剖,无需定制或组配式假体。

要点

  • 68例儿童期Perthes病行全髋关节置换术,使用一体式非骨水泥股骨柄,平均随访8.5年。
  • 术中股骨距骨折8髋(11.8%),均经环扎钢丝成功治疗。
  • 无脱位、无翻修,末次随访Harris髋关节评分平均91分。

核心结论

  • 一体式非骨水泥股骨柄在Perthes病全髋关节置换术中可可靠重建解剖,无需定制或组配式假体。

研究设计与样本

  • 回顾性分析2003年6月至2008年12月间因儿童期Perthes病行全髋关节置换术的68例连续患者,男35例、女33例,指数手术时平均年龄48岁(16至73岁),平均体重指数24.4(18.3至32.9)。
  • 68髋中Stulberg III类32髋、IV类36髋,术前患肢平均短缩17.2 mm(5至34),最小随访5年(平均8.5年;5.2至10年)。

主要发现

  • 术中股骨距骨折发生于8髋(11.8%),经环扎钢丝成功治疗。
  • 股骨柄平均前倾14.6°(-2.3至30;标准差7.3),髋臼杯平均外展40.2°(23.7至56.0;标准差6.5),平均前倾28.3°(6.4至43.0;标准差7.6)。
  • 平均随访8.5年(5.2至10年)期间无脱位发生,无髋关节翻修。
  • 末次随访时平均Harris髋关节评分为91分(59至100),平均加州大学洛杉矶分校活动评分为3.2(2至8)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Modular or custom-made femoral components have been preferred for total hip arthroplasty (THA) in patients with a history of Perthes' disease because of the distortion in the anatomy of the proximal femur. However, it has not been established whether a monobloc cementless stem will fit the distorted proximal femur or whether the results of the procedure are satisfactory in this group of patients. PATIENTS AND METHODS: We reviewed 68 consecutive patients who had undergone THA for childhood Perthes' disease between June 2003 and December 2008. There were 35 men and 33 women with a mean age of 48 years (16 to 73) at the time of index arthroplasty. Their mean body mass index was 24.4 (18.3 to 32.9). Of the 68 hips, 32 were classified as Stulberg class III and 36 as class IV. The mean pre-operative shortening of the affected leg was 17.2 mm (5 to 34). The minimum follow-up was five years (mean 8.5 years; 5.2 to 10). RESULTS: An intra-operative calcar fracture occurred in eight hips (11.8%) and was successfully treated by cerclage wiring. The mean stem version was 14.6° (-2.3 to 30; standard deviation (sd) 7.3). The mean acetabular component abduction was 40.2° (23.7 to 56.0; sd 6.5) and the mean anteversion 28.3° (6.4 to 43.0; sd 7.6), respectively. The mean follow-up was 8.5 years (5.2 to 10). No dislocations occurred and no hips were revised during the course of the study. At final follow-up, the mean Harris Hip Score was 91 points (59 to 100) and the mean University of California, Los Angeles activity score was 3.2 (2 to 8). CONCLUSION: Monobloc cementless stems reliably restore the anatomy in Perthes' disease at THA without the need for custom-made or modular implants. Cite this article: Bone Joint J 2017;99-B:440-444.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Lee KH, Jo WL, Ha YC, et al. Total hip arthroplasty using a monobloc cementless femoral stem for patients with childhood Perthes' disease. Bone Joint J. 2017. PMID: 28385931. doi:10.1302/0301-620X.99B4.BJJ-2016-0259.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。