CT扫描评估胫骨假体旋转可重复性与精确性的研究

Reproducibility and Precision of CT Scans to Evaluate Tibial Component Rotation.
PubMed 文献 · J Arthroplasty · 2017-02-01

三位关节置换专科医生独立对62例全膝关节置换术后的CT扫描测量胫骨假体旋转,至少2周后重复测量。观察者间一致性为中等(ICC=0.52),观察者内可靠性为优秀(ICC=0.81),与金标准比较精确性仅为中等(ICC=0.64)。作者支持采用标准化标准来测量CT上的胫骨假体旋转。

要点

  • 三位关节置换专科医生对62例全膝关节置换术CT测量胫骨假体旋转,观察者间一致性中等(ICC=0.52)。
  • 观察者内可靠性优秀(ICC=0.81),但与金标准比较精确性仅为中等(ICC=0.64)。
  • 作者支持采用标准化标准来测量CT上的胫骨假体旋转。

核心结论

  • 执业医生测量胫骨旋转在内部是一致的,但未能证明令人满意的精确性和观察者间一致性,作者支持采用标准化标准来测量CT上的胫骨假体旋转。

研究设计与样本

  • 三位经过专科培训的学术型关节置换外科医生使用各自选择的方法,独立对62例全膝关节置换术的CT扫描测量胫骨假体旋转,并在初次测量至少2周后重复测量。
  • 精确性评估采用正式的8步方案作为金标准,计算组内相关系数(ICC)以评估精确性、观察者间一致性和观察者内可靠性。

主要发现

  • 三位外科医生之间胫骨假体旋转的观察者间一致性为中等(ICC=0.52)。
  • 胫骨旋转的观察者内可靠性为优秀(ICC=0.81)。
  • 外科医生测量与经过验证的金标准比较显示,胫骨假体旋转的精确性仅为中等(ICC=0.64)。

关键数值与推荐

  • 观察者间一致性ICC=0.52,观察者内可靠性ICC=0.81,与金标准比较精确性ICC=0.64。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Component rotation likely plays a greater role on the survivorship and outcomes of total knee arthroplasties than is currently known. Our goal was to evaluate the precision, interobserver reliability, and intrarater reliability of tibial component rotation as measured by computed tomography (CT) scan, regardless of measurement technique. METHODS: Three fellowship-trained, academic arthroplasty surgeons independently measured tibial component rotation on CT scans of 62 total knee arthroplasties using their methods of choice. Measurements were repeated at least 2 weeks after the initial measurement. The precision of the measurements was assessed using a formal 8-step protocol as the gold standard. Intraclass correlation coefficients (ICCs) were calculated to evaluate precision, interobserver agreement, and intrarater reliability RESULTS: The interobserver agreement between the 3 surgeons for tibial component rotation was also moderate (ICC = 0.52). The intrarater reliability of tibial rotation was excellent (ICC = 0.81). Comparison of surgeons' measurement to a validated gold standard revealed only moderate precision for tibial component rotation (ICC = 0.64). CONCLUSION: Practicing surgeons measuring tibial rotation were internally consistent, but failed to demonstrate satisfactory precision and interobserver agreement. We support the adoption of standardized criteria for the measurement of tibial component rotation on CT scans.

来源:J Arthroplasty,查看原文。版权归原作者所有。