本研究采用随机完全区组动物脊柱植入物感染模型,在5只新西兰白兔的T4、T9、L1、L6椎旁植入钛丝,以T9为无菌内对照,其余部位接种不同菌落形成单位的大肠埃希菌(ATCC 25922),术后4天评估感染。结果发现最低接种量10 CFU不能可靠致感染,10 CFU可一致引起软组织感染但植入物感染不一致,需10 CFU才能一致产生软组织和植入物感染。
要点
- 无菌对照部位均未观察到感染证据。
- 最低接种量10 CFU的大肠埃希菌未产生可靠感染。
- 接种10 CFU可一致产生软组织和植入物感染。
核心结论
- 接种10 CFU大肠埃希菌可一致产生软组织和植入物感染,该动物模型可可靠复制脊柱内固定相关的革兰阴性感染。
研究设计与样本
- 随机完全区组动物脊柱植入物感染模型,设内部对照,使用5只新西兰白兔。
- 在T4、T9、L1、L6椎旁植入5 mm钛丝模拟后路脊柱内固定,以T9为无菌内对照,其余部位接种不同接种量的大肠埃希菌(ATCC 25922)。
- 术后4天处死动物,检测植入物及周围组织的细菌载量。
主要发现
- 无菌对照部位均未观察到感染证据。
- 最低接种量10 CFU的大肠埃希菌未产生可靠感染。
- 接种10 CFU可一致引起软组织感染,但植入物感染不一致。
- 接种10 CFU才能一致产生软组织和植入物感染。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: A randomized complete block animal spinal implant infection model with internal control. OBJECTIVE: The aim of this study was to develop a spinal implant animal infection model to simulate postoperative gram-negative wound infection. SUMMARY OF BACKGROUND DATA: Implant-associated surgical site infections (SSIs) remain a dreaded complication of spinal surgery. Currently, over 30% of all spine SSIs are secondary to gram-negative bacteria. Traditional animal models have utilized gram-positive inoculums to simulate postoperative infection, but there exists no model in the literature for gram-negative infection in the setting of spinal instrumentation. METHODS: Five New Zealand white female rabbits underwent simulated partial laminectomies and implantation of a 5 mm titanium wire adjacent to the spinous processes of vertebra T4, T9, L1, and L6 to mimic posterior spinal instrumentation. The second site, T9, was used as the sterile internal control sites, while all other sites were challenged with varying inoculums of Escherichia coli (EC American Type Culture Collection 25922): 10, 10, 10, 10, and 10 Colony Forming Units (CFU). The rabbits were sacrificed 4 days postoperatively and bacterial loads were assayed from the implants and surrounding tissue. RESULTS: No evidence for infection was observed in any of the sterile control sites. The lowest inoculum of E. coli (10 CFU) did not produce a reliable infection. Inoculation with 10 CFU created a consistent soft tissue infection, but inconsistent infection on implants. Inoculation with 10 CFU was required to consistently produce both soft tissue and implant infection. CONCLUSION: Consistent soft tissue and implant infection was produced with inoculation of 10 CFU of E. coli. Gram-negative infections represent greater than 30% of all spinal SSIs, and this animal model can reliably reproduce such infections with spinal instrumentation that can guide future development of anti-infective therapies. LEVEL OF EVIDENCE: 2.
引用
- Laratta JL, Shillingford JN, Hardy N, et al. A Dose-Response Curve for a Gram-Negative Spinal Implant Infection Model in Rabbits. Spine (Phila Pa 1976). 2017. PMID: 28441310. doi:10.1097/BRS.0000000000002205
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。