基于吲哚菁绿荧光关节镜评估不同修复构型下肩袖肌腱灌注的初步报告
在10只兔急性肩袖修复模型中,用吲哚菁绿荧光相机比较平行经骨修复与缝线桥构型修复后的肌腱灌注。修复后即刻缝线桥构型荧光强度弱于平行经骨修复(65.9±47.6 vs 84.3±53.4每像素,P=.003);3天时仍较弱但未达统计学显著(52.5±13.7 vs 60.2±22.7每像素,P=.077)。作者认为缝线桥构型在压迫区阻碍肌腱灌注,可能影响愈合与失败模式。
要点
- 兔急性肩袖修复后即刻,缝线桥构型荧光强度弱于平行经骨修复(P=.003)。
- 修复后3天缝线桥构型荧光仍较弱,但差异未达统计学显著(P=.077)。
- 与健康肌腱相比,平行经骨修复荧光为83.2%±9.5%,缝线桥构型为63.2%±13.2%。
核心结论
- 吲哚菁绿荧光相机系统可在兔急性肩袖修复模型中检测荧光;缝线桥构型修复后即刻肌腱灌注较差,3天时荧光强度仍较差但未达统计学显著。
研究设计与样本
- 控制性实验室研究,在10只兔的肩关节行急性肩袖修复,双肩分别采用平行经骨修复或缝线桥构型修复。
- 另设附属研究比较每种修复方法与健康肌腱,共纳入6只兔(每组比较3只)。
主要发现
- 修复后即刻10个标本的吲哚菁绿荧光平均灰度强度缝线桥构型弱于平行经骨修复(65.9±47.6 vs 84.3±53.4每像素,P=.003)。
- 修复后3天因缝线桥构型组2个标本缝线失效,8个标本纳入分析,缝线桥构型荧光强度仍弱于平行经骨修复(52.5±13.7 vs 60.2±22.7每像素,P=.077)。
- 与健康肌腱相比,平均荧光强度平行经骨修复为83.2%±9.5%,缝线桥构型为63.2%±13.2%。
临床怎么用
- 作者认为缝线桥构型修复在肌腱压迫区阻碍灌注,该发现可能影响肩袖肌腱愈合和失败模式。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The disturbance of rotator cuff tendon perfusion has been connected with the suture-bridge configuration repair (SBCR) technique; however, in vivo assessments of the tendon blood supply have been problematic with other modalities. An evaluation of tissue perfusion by an indocyanine green (ICG) fluorescence arthroscope has been developed to counteract this difficulty. PURPOSE: To verify the hindrance of perfusion in SBCR, we used an ICG fluorescence camera to compare parallel-type transosseous repair (PTR) and SBCR in rabbits immediately and at 3 days after rotator cuff repair. STUDY DESIGN: Controlled laboratory study. METHODS: Acute rotator cuff repair was performed on the shoulders of 10 rabbits. Both shoulders were repaired using either PTR or SBCR. For PTR, simple repair was performed through 2 parallel transosseous tunnels created using a microdrill. For SBCR, 2 additional crisscross transosseous tunnels were added to mimic arthroscopic SBCR. Immediately after repair, ICG was injected through the ear vein, and images were recorded using an ICG fluorescence camera. Tendon perfusion was compared by measuring fluorescence intensity using ImageJ software in both methods. At 3 days after rotator cuff repair, a reassessment of ICG fluorescence was performed. In addition, as a subsidiary study, a comparison of each repair method and a healthy tendon was performed (PTR vs healthy tendon and SBCR vs healthy tendon). Six rabbits (3 for each comparison) were included. RESULTS: Immediately after rotator cuff repair, the mean (±SD) grayscale intensity of ICG fluorescence was weaker in SBCR than PTR in 10 specimens (65.9 ± 47.6 vs 84.3 ± 53.4 per pixel, respectively; P = .003). At 3 days after repair, 8 specimens were included in the analysis because suture strands failed in 2 specimens in SBCR. The mean intensity of fluorescence was still weaker in SBCR compared with PTR (52.5 ± 13.7 vs 60.2 ± 22.7 per pixel, respectively; P = .077). The mean fluorescence intensity compared with a healthy tendon was 83.2% ± 9.5% in PTR and 63.2% ± 13.2% in SBCR. CONCLUSION: Our ICG fluorescence camera system was able to detect ICG fluorescence in an acute rabbit rotator cuff repair model. SBCR showed inferior tendon perfusion immediately after repair. At 3 days after repair, SBCR still showed inferior fluorescence intensity, although it did not reach statistical significance. CLINICAL RELEVANCE: In this study, SBCR hindered perfusion at the tendon in the compressed area. This finding may affect rotator cuff tendon healing and failure mode.
引用
- Kim SH, Cho WS, Joung HY, et al. Perfusion of the Rotator Cuff Tendon According to the Repair Configuration Using an Indocyanine Green Fluorescence Arthroscope: A Preliminary Report. Am J Sports Med. 2016. PMID: 28272929. doi:10.1177/0363546516669778
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。