文献速递运动医学关节外科

关节镜下肩袖修复采用经骨隧道缝合技术的优势:一项前瞻性随机对照试验

Advantages of Arthroscopic Rotator Cuff Repair With a Transosseous Suture Technique: A Prospective Randomized Controlled Trial.
PubMed 文献 · Am J Sports Med · 2017-03-24

纳入69例肩袖撕裂患者,35例采用金属锚钉单排固定,34例采用标准化经骨隧道无硬件缝合修复。经骨隧道组术后疼痛下降更快,第3周NRS均值3.00 vs 2.46(P=0.02),第4周2.44 vs 1.76(P<0.01);最终随访两组功能结果无差异,再撕裂率无显著差异(P=0.81)。

要点

  • 经骨隧道组术后第3周NRS均值2.46 vs 锚钉组3.00(P=0.02),疼痛更轻。
  • 第4周NRS均值经骨隧道组1.76 vs 锚钉组2.44(P<0.01)。
  • 最终随访两组功能结果无差异,再撕裂率无显著差异(P=0.81)。

核心结论

  • 两种关节镜下肩袖修复技术在功能和影像学结果上无显著差异,但经骨隧道术后疼痛下降更快,作者认为这可能是肩袖手术修复的一种改进。

研究设计与样本

  • 随机对照试验,证据等级1级;共纳入69例肩袖撕裂患者,35例采用金属锚钉固定,34例采用标准化经骨隧道修复。
  • 术前、术后28天内及术后至少1年采用经验证的评分量表(Constant评分、QuickDASH、数字评分量表[NRS])进行临床评估;最终随访在3年以上通过QuickDASH评估以检测与之前随访的差异;随访期间通过磁共振成像按Sugaya 5分类法判定肩袖完整性。
  • 试验注册号:NCT01815177(ClinicalTrials.gov标识符)。

主要发现

  • 经骨隧道技术组患者疼痛显著更轻,尤其从术后第15天起:第3周锚钉组NRS均值3.00 vs 经骨隧道组2.46(P=0.02);第4周分别为2.44 vs 1.76(P<0.01)。
  • 最终评估时两组功能结果无差异。
  • 基于Sugaya磁共振成像分类评估肩袖修复完整性,两种技术再撕裂率无显著差异(P=0.81)。

关键数值与推荐

  • 第3周NRS均值:锚钉组3.00 vs 经骨隧道组2.46(P=0.02)。
  • 第4周NRS均值:锚钉组2.44 vs 经骨隧道组1.76(P<0.01)。
  • 再撕裂率比较P=0.81。

临床怎么用

  • 原文结论未据此给出具体推荐,仅指出经骨隧道术后疼痛下降更快,作者认为这可能是肩袖手术修复的一种改进。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rotator cuff tear is a common finding in patients with painful, poorly functioning shoulders. The surgical management of this disorder has improved greatly and can now be fully arthroscopic. PURPOSE: To evaluate clinical and radiological results of arthroscopic rotator cuff repair using 2 different techniques: single-row anchor fixation versus transosseous hardware-free suture repair. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: Sixty-nine patients with rotator cuff tears were enrolled: 35 patients were operated with metal anchors and 34 with standardized transosseous repair. The patients were clinically evaluated before surgery, during the 28 days after surgery, and at least 1 year after the operation by the use of validated rating scores (Constant score, QuickDASH, and numerical rating scale [NRS]). Final follow-up was obtained at more than 3 years by a QuickDASH evaluation to detect any difference from the previous follow-up. During the follow-up, rotator cuff integrity was determined through magnetic resonance imaging and was classified according to the 5 Sugaya categories. RESULTS: Patients operated with the transosseous technique had significantly less pain, especially from the 15th postoperative day: In the third week, the mean NRS value for the anchor group was 3.00 while that for transosseous group was 2.46 ( P = .02); in the fourth week, the values were 2.44 and 1.76, respectively ( P < .01). No differences in functional outcome were noted between the 2 groups at the final evaluation. In the evaluation of rotator cuff repair integrity, based on Sugaya magnetic resonance imaging classification, no significant difference was found between the 2 techniques in terms of retear rate ( P = .81). CONCLUSION: No significant differences were found between the 2 arthroscopic repair techniques in terms of functional and radiological results. However, postoperative pain decreased more quickly after the transosseous procedure, which therefore emerges as a possible improvement in the surgical repair of the rotator cuff. Registration: NCT01815177 ( ClinicalTrials.gov identifier).

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Randelli P, Stoppani CA, Zaolino C, et al. Advantages of Arthroscopic Rotator Cuff Repair With a Transosseous Suture Technique: A Prospective Randomized Controlled Trial. Am J Sports Med. 2017. PMID: 28339286. doi:10.1177/0363546517695789

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。