文献速递关节外科

创新临床代表性小鼠假体周围感染模型中假体周围细菌载量及体内生物膜形成的定量分析

Quantification of Peri-Implant Bacterial Load and in Vivo Biofilm Formation in an Innovative, Clinically Representative Mouse Model of Periprosthetic Joint Infection.
PubMed 文献 · J Bone Joint Surg Am · 2017-01-01

研究建立了一种使用三维打印Ti-6Al-4V植入物的小鼠假体周围感染模型,25只12周龄C57BL/6小鼠接受单侧胫骨近端植入物并关节内注射3×10 CFU金黄色葡萄球菌Xen 36或生理盐水。感染小鼠出现行走困难、无菌性植入物松动的影像学表现和炎症标志物显著升高,假体周围组织2周和6周平均细菌载量分别为4.46×10 CFU和2.53×10 CFU,植入物表面可定量存活细菌,扫描电镜显示生物膜内成簇金黄色葡萄球菌。

要点

  • 感染小鼠随时间出现行走困难、影像学显示感染性植入物松动、炎症标志物显著升高。
  • 感染动物假体周围组织2周平均4.46×10 CFU、6周平均2.53×10 CFU金黄色葡萄球菌。
  • 扫描电镜显示植入物表面生物膜内包裹成簇金黄色葡萄球菌球菌。

核心结论

  • 该动物模型是据作者所知迄今最具临床代表性的假体周围感染复制模型。
  • 该模型首次通过推测临床发生感染的相同方法产生感染,使用可骨整合的承重植入物,并提供包括影像学特征、炎症标志物和细菌载量在内的8个方面定量数据。

研究设计与样本

  • 研究使用25只12周龄C57BL/6小鼠,接受单侧胫骨近端植入物及关节内注射3×10 CFU金黄色葡萄球菌Xen 36或生理盐水。
  • 植入物为三维打印Ti-6Al-4V,可承重并允许定量分析假体周围细菌载量和评估生物膜。
  • 术后进行步态分析、膝关节X线片和血清炎症标志物测量;于2周或6周安乐死后,匀浆骨与软组织定量假体周围组织内细菌,植入物经超声处理定量黏附细菌或扫描电镜表征生物膜。

主要发现

  • 所有小鼠均存活手术且无全身性脓毒症。
  • 对照小鼠立即耐受承重,炎症标志物正常,影像学显示骨整合征象。
  • 感染小鼠随时间出现行走困难,影像学显示感染性植入物松动,炎症标志物显著升高。
  • 感染动物假体周围组织2周平均4.46×10 CFU金黄色葡萄球菌,6周平均2.53×10 CFU。
  • 回收植入物表面可定量存活金黄色葡萄球菌,扫描电镜显示生物膜内包裹成簇金黄色葡萄球菌球菌。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Periprosthetic joint infection (PJI) is a devastating complication following total joint arthroplasty. Current animal models of PJI are limited because of a lack of quantitative methods and failure to effectively recreate the periprosthetic space. We therefore developed a murine PJI model involving a 3-dimensionally printed Ti-6Al-4V implant capable of bearing weight and permitting quantitative analysis of periprosthetic bacterial load and evaluation of biofilm. METHODS: Twenty-five 12-week-old C57BL/6 mice received a unilateral proximal tibial implant and intra-articular injection of either 3 × 10 colony forming units (CFUs) of Staphylococcus aureus Xen 36 or saline solution. Postoperatively, mice underwent gait analysis, knee radiographs, and serum inflammatory marker measurements. Following euthanasia at 2 or 6 weeks, bone and soft tissues were homogenized to quantify bacteria within periprosthetic tissues. Implants were either sonicated to quantify adherent bacteria or examined under scanning electron microscopy (SEM) to characterize biofilm. RESULTS: All mice survived surgery and were not systemically septic. The control mice immediately tolerated weight-bearing and had normal inflammatory markers and radiographic signs of osseointegration. Infected mice had difficulty walking over time, exhibited radiographic findings of septic implant loosening, and had significantly elevated inflammatory markers. Periprosthetic tissues of the infected animals displayed a mean of 4.46 × 10 CFUs of S. aureus at 2 weeks and 2.53 × 10 CFUs at 6 weeks. Viable S. aureus was quantified on retrieved implant surfaces. SEM demonstrated S. aureus cocci in clusters encased within biofilm. CONCLUSIONS: This animal model is, to our knowledge, the most clinically representative PJI replication to date. It is the first that we know of to produce infection through the same method hypothesized to occur clinically, utilize a weight-bearing implant that can osseointegrate, and provide quantitative data on 8 aspects of PJI, including radiographic features, inflammatory markers, and bacterial loads. CLINICAL RELEVANCE: This novel animal model is, to our knowledge, the first to provide a load-bearing translational representation of clinical PJI that effectively recreates the periprosthetic space.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Carli AV, Bhimani S, Yang X, et al. Quantification of Peri-Implant Bacterial Load and in Vivo Biofilm Formation in an Innovative, Clinically Representative Mouse Model of Periprosthetic Joint Infection. J Bone Joint Surg Am. 2017. PMID: 28291188. doi:10.2106/JBJS.16.00815

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。