金属离子趋势在预测金属对金属全髋关节置换翻修中的效用

The Utility of Metal Ion Trends in Predicting Revision in Metal-on-Metal Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-02-20

该研究回顾性分析了59例(69髋)关节表面置换全髋关节置换术患者的翻修前钴和铬浓度随时间变化。结果显示翻修患者中71%(12/17)有多次离子测量者表现为钴离子水平升高或持续高值;铬水平高于7 ppb时翻修风险显著增加(HR 22.35,P=0.001),钴水平高于7 ppb时假瘤形成风险显著增加(HR 6.88,P=0.027)。作者认为钴和铬水平分别超过5和2.5 ppb即开始显示ARMD风险增加,应作为与患者讨论未来翻修可能性的较低 cutoff 值。

要点

  • 翻修患者中71%(12/17)有多次离子测量者表现为钴离子水平升高或持续高值。
  • 铬水平高于7 ppb时翻修风险显著增加(HR 22.35,P=0.001)。
  • 钴水平高于7 ppb时假瘤形成风险显著增加(HR 6.88,P=0.027)。

核心结论

  • 钴和铬水平分别超过5和2.5 ppb即开始显示ARMD风险增加,应作为与患者讨论未来翻修可能性的较低 cutoff 值。

研究设计与样本

  • 回顾性分析59例(69髋)关节表面置换全髋关节置换术患者,审查翻修前钴和铬浓度随时间变化。

主要发现

  • 翻修患者中71%(12/17)有多次离子测量者表现为钴离子水平升高或持续高值。
  • 钴和铬水平分别从12和4 ppb开始呈现翻修风险升高趋势,铬水平高于7 ppb时显著(HR 22.35,P=0.001)。
  • 钴和铬水平分别从5和2.5 ppb开始呈现假瘤形成风险升高趋势,钴水平高于7 ppb时显著(HR 6.88,P=0.027)。

关键数值与推荐

  • 铬水平高于7 ppb与翻修风险显著相关(HR 22.35,P=0.001)。
  • 钴水平高于7 ppb与假瘤形成风险显著相关(HR 6.88,P=0.027)。

临床怎么用

  • 作者认为钴和铬水平分别超过5和2.5 ppb应作为与患者讨论未来翻修可能性的较低 cutoff 值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is a paucity of data examining metal ion levels over time. METHODS: We retrospectively reviewed 59 patients (69 hips) with an articular surface replacement total hip arthroplasty. We reviewed prerevision cobalt and chromium concentrations over time. RESULTS: Seventy-one percent of patients who were revised and had multiple ion measurements (12/17) demonstrated increasing cobalt ion levels or elevated ion levels over time. There was a trend toward an elevated risk of revision for increasing cobalt and chromium levels starting at 12 and 4 ppb, respectively; this was significant for chromium levels above 7 ppb (hazard ratio 22.35, P = .001). Similarly, there was a trend toward an elevated risk of pseudotumor formation for increasing cobalt and chromium levels starting at 5 and 2.5 ppb, respectively; this was significant for cobalt levels above 7 ppb (hazard ratio 6.88, P = .027). CONCLUSION: In this paper, cobalt and chromium levels levels above 5 and 2.5 ppb started to demonstrate an increased risk of ARMD, and should be considered as a lower cutoff for discussion with patients about the potential for future revision.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Carlson BC, Bryan AJ, Carrillo-Villamizar NT, et al. The Utility of Metal Ion Trends in Predicting Revision in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty. 2017. PMID: 28320566. doi:10.1016/j.arth.2017.02.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。