髋臼假体位置不良增加金属对金属全髋关节置换翻修风险
该回顾性研究纳入2000至2013年间825例(976髋)金属对金属髋关节置换患者,评估髋臼杯外展角与前倾角对翻修风险的影响。髋臼杯位于Lewinnek安全区外者翻修风险比为1.82(95%CI 1.26-2.62;P=.0014)。
要点
- 58.5%的髋臼杯位于Lewinnek安全区外,16.1%的髋接受翻修。
- 翻修髋中69.2%的髋臼杯角度位于Lewinnek安全区外。
- 髋臼杯位于安全区外者翻修风险比为1.82(95%CI 1.26-2.62;P=.0014)。
核心结论
- 髋臼杯位置位于Lewinnek安全区外与金属对金属髋关节置换患者翻修风险增加相关。
研究设计与样本
- 回顾性研究纳入2000至2013年间接受金属对金属髋关节置换的825例患者(976髋),其中男性474例、女性351例,平均年龄58岁(范围19-86岁)。
主要发现
- 髋臼杯平均外展角48.9°(标准差8.1°;范围16°-76°),平均前倾角20.6°(标准差9.9°;范围-25°至46°)。
- 571髋(58.5%)的髋臼杯位于Lewinnek安全区外,157髋(16.1%)接受了髋臼杯翻修手术。
- 翻修髋中69.2%的髋臼杯角度位于Lewinnek安全区外。
- 髋臼杯外展角与前倾角测量的观察者间信度与观察者内重复性极好(组内相关系数>0.90)。
- 髋臼杯位于Lewinnek安全区外与安全区内相比,翻修的比值比为1.82(95%置信区间1.26-2.62;P=.0014)。
关键数值与推荐
- 可接受的髋臼杯位置定义为位于Lewinnek安全区内。
- 髋臼杯位于Lewinnek安全区外的翻修比值比为1.82(95%置信区间1.26-2.62;P=.0014)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The rate of and the reasons for the failure of metal-on-metal (MoM) bearings have recently been discussed in literature. The aim of this study was to evaluate the influence of acetabular cup inclination and version angles on revision risk in patients with MoM hip arthroplasty. METHODS: We retrospectively reviewed 825 patients (976 hips) who underwent a MoM hip arthroplasty between 2000 and 2013. There were 474 men and 351 women, with a mean age of 58 (19-86) years. Acceptable cup orientation was considered to be inside the Lewinnek's safe zone. RESULTS: The mean acetabular inclination angle was 48.9° (standard deviation, 8.1°; range, 16°-76°) and version angle 20.6° (standard deviation, 9.9°; range, -25 to 46°). The cup was found to be outside the Lewinnek's safe zone in 571 hips (58.5%). Acetabular cup revision surgery was performed in 157 hips (16.1%). The cup angles were outside Lewinnek's safe zone in 69.2% of the revised hips. The mean interobserver reliability and intraobserver repeatability of the measurements of cup inclination and version angles were excellent (intraclass correlation coefficients >0.90). The odds ratio for revision in hips outside vs inside the Lewinnek's safe zone was 1.82 (95% confidence interval, 1.26-2.62; P = .0014). CONCLUSION: Our findings provide compelling evidence that a cup position outside the Lewinnek's safe zone is associated with increased revision risk in patients with MoM arthroplasty.