假体超声裂解培养提高假体周围关节感染培养的准确性
研究对2012至2016年间565例翻修全髋和全膝关节置换的取出假体行超声裂解液培养,最终503例纳入分析,以MSIS标准诊断假体周围关节感染。超声裂解培养敏感性高于滑液培养和组织培养,特异性无显著差异;325例 presumed aseptic 翻修中53例(16%)超声裂解培养阳性。
要点
- 超声裂解培养敏感性97%,高于滑液培养57%和组织培养70%。
- 超声裂解培养特异性90%,与滑液培养和组织培养无显著差异。
- 325例 presumed aseptic 翻修中53例(16%)超声裂解培养阳性。
核心结论
- 在关节置换翻修中常规使用假体超声裂解培养可提高检测临床感染和隐匿感染中细菌存在的诊断敏感性。
- 未来研究需要细化用于确定临床感染和治疗指征的菌落形成单位阈值。
研究设计与样本
- 2012年至2016年对565例翻修全髋和全膝关节置换的取出假体行超声裂解液培养,排除标准包括数据不足以确定MSIS分类、仅真菌培养和无菌落形成单位报告,最终503例纳入分析。
- 以MSIS标准诊断假体周围关节感染,503例中178例(35%)诊断为感染,325例(65%)诊断为无感染。
- 325例无感染中53例(16%)超声裂解培养阳性,其中25例(47%)随访至少2年。
- 证据等级为Level III,诊断性研究。
主要发现
- 超声裂解培养敏感性97%(89%-99%),高于滑液培养57%(44%-69%)(p < 0.001)和组织培养70%(58%-80%)(p < 0.001)。
- 超声裂解培养特异性90%(72%-97%),与滑液培养100%(86%-100%)无显著差异(p = 0.833),与组织培养97%(81%-100%)无显著差异(p = 0.317)。
- 假体周围关节感染中,滑液、组织和/或超声裂解培养鉴定最多的五种细菌为凝固酶阴性葡萄球菌26%(89/267)、甲氧西林敏感金黄色葡萄球菌19%(65/267)、耐甲氧西林金黄色葡萄球菌12%(43/267)、α-溶血性链球菌5%(19/267)和粪肠球菌5%(19/267)。
- 325例 presumed aseptic 翻修中53例(16%)超声裂解培养阳性。
- 53例培养阳性的 presumed aseptic 翻修患者中34%(18/53)接受了抗感染抗生素治疗,8%(4/53)接受了二次翻修。
关键数值与推荐
- 假体周围关节感染诊断采用MSIS标准。
- 超声裂解培养敏感性97%(89%-99%)vs 滑液培养57%(44%-69%)(p < 0.001)。
- 超声裂解培养敏感性97%(89%-99%)vs 组织培养70%(58%-80%)(p < 0.001)。
- 超声裂解培养特异性90%(72%-97%)vs 滑液培养100%(86%-100%)(p = 0.833)。
- 超声裂解培养特异性90%(72%-97%)vs 组织培养97%(81%-100%)(p = 0.317)。
临床怎么用
- 作者认为在关节置换翻修中常规使用假体超声裂解培养可提高诊断敏感性。
- 作者指出未来研究需要细化用于确定临床感染和治疗指征的菌落形成单位阈值。
局限性
- 未来研究需要细化用于确定临床感染和治疗指征的菌落形成单位阈值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is evidence that sonication of explanted prosthetic hip and knee arthroplasty components with culture of the sonication fluid may enhance diagnostic sensitivity. Previous studies on the use of implant sonicate cultures have evaluated diagnostic thresholds but did not elaborate on the clinical importance of positive implant sonicate cultures in the setting of presumed aseptic revisions and did not utilize consensus statements on periprosthetic joint infection (PJI) diagnosis when defining their gold standard for infection. QUESTIONS/PURPOSES: (1) How do implant sonicate cultures compare with preoperative synovial fluid cultures and intraoperative tissue cultures in the diagnosis of PJI in both THA and TKA when compared against Musculoskeletal Infection Society (MSIS) criteria for PJI? (2) Utilizing implant sonicate cultures, what is the relative prevalence of bacterial species identified in PJIs? (3) What is the incidence of positive implant sonicate cultures in the setting of presumed aseptic revision hip and knee arthroplasty procedures, and what treatments did they receive? METHODS: Between 2012 and 2016 we performed implant sonicate fluid cultures on surgically removed implants from 565 revision THAs and TKAs. Exclusion criteria including insufficient data to determine Musculoskeletal Infection Society (MSIS) classification, fungal-only cultures, and absence of reported colony-forming units decreased the number of procedures to 503. Procedures represented each instance of revision surgery (sometimes multiple in the same patient). Of those, a definitive diagnosis of infection was made using the MSIS criteria in 178 of 503 (35%), whereas the others (325 of 503 [65%]) were diagnosed as without infection. A total of 53 of 325 (16%) were considered without infection based on MSIS criteria but had a positive implant sonicate culture. Twenty-five of 53 (47%) of these patients were followed for at least 2 years. The diagnosis of PJI was determined using the MSIS criteria. RESULTS: Sensitivity of implant sonicate culture was greater than synovial fluid culture and tissue culture (97% [89%-99%] versus 57% [44%-69%], p < 0.001; 97% [89%-99%] versus 70% [58%-80%], p < 0.001, respectively). The specificity of implant sonicate culture was not different from synovial fluid culture or tissue culture with the numbers available (90% [72%-97%] versus 100% [86%-100%], p = 0.833; 90% [72%-97%] versus 97% [81%-100%], p = 0.317, respectively). Coagulase-negative Staphylococcus was the most prevalent organism for both procedure types. In PJIs, the five most frequent bacteria identified by synovial fluid, tissue, and/or implant sonicate cultures were coagulase-negative Staphylococcus (26% [89 of 267]), methicillin-susceptible Staphylococcus aureus (19% [65 of 267]), methicillin-resistant S. aureus (12% [43 of 267]), α-hemolytic Streptococci (5% [19 of 267]), and Enterococcus faecalis (5% [19 of 267]). Fifty-three of 325 (16%) presumed aseptic revisions had a positive sonication culture. Thirty-four percent (18 of 53) of culture-positive aseptic revision patients received antibiotic treatment for infection and 8% (4 of 53) underwent a secondary revision. CONCLUSIONS: The routine use of implant sonicate cultures in arthroplasty revisions improves the diagnostic sensitivity for detecting the presence of bacteria in both clinical and occult infections. Future studies will need to refine colony-forming unit thresholds for determining clinical infection and indications for treatment. LEVEL OF EVIDENCE: Level III, diagnostic study.
引用
- Rothenberg AC, Wilson AE, Hayes JP, et al. Sonication of Arthroplasty Implants Improves Accuracy of Periprosthetic Joint Infection Cultures. Clin Orthop Relat Res. 2017. PMID: 28290115. doi:10.1007/s11999-017-5315-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。