股骨颈干角过小畸形患者全髋关节置换术中的转子成形术
研究纳入30例(31髋)股骨颈干角过小畸形接受转子成形术全髋关节置换的患者,平均随访5年。所有股骨柄均中立位插入,无翻修,假体均骨长入稳定,Harris髋关节评分从66.9分改善至89.4分。作者认为转子成形术可避免股骨柄内翻插入而不损害外展肌机制。
要点
- 转子成形术在全髋关节置换中切除大转子内侧半,用于股骨颈干角过小畸形。
- 30例(31髋)平均随访5年,所有股骨柄中立位插入,无翻修。
- Harris髋关节评分从66.9分改善至89.4分,假体均骨长入稳定。
核心结论
- 转子成形术可用于股骨颈干角过小畸形患者全髋关节置换术中避免股骨柄内翻插入,且不损害外展肌机制。
研究设计与样本
- 评估30例(31髋)股骨颈干角过小畸形并接受转子成形术全髋关节置换的患者,平均随访5年(范围3-9年)。
主要发现
- 所有股骨柄均中立位插入。
- 术后2个月跌倒后发生1例Vancouver 1型假体周围股骨骨折。
- 末次随访时外展肌平均肌力4.3级(范围3-5级)。
- 4例患者中度跛行,26例患者轻度跛行。
- 90°屈曲位外展范围为15°至45°(平均35°)。
临床怎么用
- 作者认为,转子成形术可用于股骨颈干角过小畸形患者全髋关节置换术中避免股骨柄内翻插入,且不损害外展肌机制。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In total hip arthroplasty (THA) of hips with coxa vara, the femoral stems might be inserted in a varus alignment. To avoid varus insertion, we designed a technique, which we termed "trochantoplasty." In this procedure, the medial half of the greater trochanter was removed during THA. METHODS: We evaluated 30 patients (31 hips) who had coxa vara deformity and underwent THA using trochantoplasty at the mean follow-up of 5 years (range, 3-9 years). RESULTS: All stems were inserted in the neutral position. One Vancouver type 1 periprosthetic femoral fracture occurred after a fall at postoperative 2 months. At the latest follow-up, the mean power of abductor was 4.3 (range, 3-5). Four patients had moderate limp whereas 26 patients had slight limp. The abduction at 90° flexion ranged from 15° to 45° (mean, 35°). There was no revision. All prostheses had bone-ingrown stability without any detectable wear or osteolysis. The mean Harris hip score was improved from 66.9 to 89.4 points. CONCLUSION: Trochantoplasty can be used to avoid varus insertion of the femoral stem while performing THA in patients with coxa vara deformity without compromising the abductor mechanism.
引用
- Yoo JI, Parvizi J, Song JU, et al. Trochantoplasty for Total Hip Arthroplasty in Patients With Coxa Vara Deformity. J Arthroplasty. 2017. PMID: 28262457. doi:10.1016/j.arth.2017.02.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。