低剂量辐射三维术中成像:能低到什么程度?一项O-Arm、CT扫描与尸体研究

Low-Dose Radiation 3D Intraoperative Imaging: How Low Can We Go? An O-Arm, CT Scan, Cadaveric Study.
PubMed 文献 · Spine (Phila Pa 1976) · 2017-01-01

该尸体研究在8具尸体T1至S1双侧置入椎弓根螺钉,比较O-Arm低剂量、极低剂量和超低剂量与CT及大体解剖识别螺钉位置的准确性。结果显示各剂量O-Arm与CT准确性相似,极低剂量与CT观察者间信度较高,但约30%内侧穿破被误分类。

要点

  • O-Arm低剂量、极低剂量和超低剂量与CT相比,识别螺钉位置准确性相似。
  • 极低剂量O-Arm和CT的观察者间信度较高,超低剂量和低剂量信度中等。
  • 约30%内侧螺钉穿破被误分类。

核心结论

  • 与大体解剖相比,O-Arm各剂量和CT评估椎弓根螺钉置入的准确性相似。
  • 极低剂量和CT的观察者间信度较高。
  • 约30%内侧螺钉穿破被误分类。
  • 超低剂量和极低剂量可在上述局限内用于术中导航和评估。

研究设计与样本

  • 尸体研究,8具尸体从T1至S1双侧置入椎弓根螺钉。
  • 螺钉随机通过O-Arm导航置入骨内、前外侧穿破和内侧穿破三种位置。
  • O-Arm图像在低剂量(kVp120/mAs125,厂家推荐最低剂量)、极低剂量(kVp120/mAs63)和超低剂量(kVp120/mAs39)三种设置下获取。
  • CT扫描采用机构低剂量方案(kVp100/mAs50),并以大体解剖确定螺钉位置。

主要发现

  • 低剂量、极低剂量、超低剂量和CT相对于大体解剖识别「IN」螺钉,所有三名观察者的平均(标准差)灵敏度为84.2%(±5.7),特异度为76.1%(±9.3),准确性为79.9%(±3.1)。
  • 观察者间一致性:低剂量0.67(0.61-0.72),极低剂量0.74(0.69-0.79),超低剂量0.61(0.56-0.66),CT 0.79(0.74-0.84)。
  • 有效辐射剂量(mSV):低剂量O-Arm扫描2.16,极低剂量1.08,超低剂量0.68,机构低剂量CT方案1.05。

临床怎么用

  • 超低剂量和极低剂量可在约30%内侧穿破被误分类的局限内用于术中导航和评估。

局限性

  • 约30%内侧螺钉穿破被误分类。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: MINI: The objective of this study was to evaluate the accuracy and reliability of pedicle screw placement using O-Arm at dosages below the manufactured recommended dose. O-Arm at reduced dose showed a 90% accuracy when compared with computed tomography; however, about 30% medial breaches were misclassified. STUDY DESIGN: Cadaveric study. OBJECTIVE: The objective was to evaluate O-Arm's ability at low-dose (LD) settings to assess intraoperative screw placement. SUMMARY OF BACKGROUND DATA: Accurate placement of pedicle screws is crucial because of proximity to vital structures. Malposition of screws may result in significant morbidity and potential mortality. O-arm provides real-time, intraoperative imaging of patient's anatomy and provides higher accuracy in scoliosis surgeries, avoiding risk to vital structures. We hypothesize using LD or ultra-low doses (ULDs) to obtain intraoperative images allow for accurate assessment of screw placement, both minimizing radiation exposure and preventing screw misplacement. METHODS: Eight cadavers were instrumented with pedicle screws bilaterally from T1 to S1. Screws were randomly placed using O-arm navigation into three positions: contained within the bone, OUT-anterior/lateral, and OUT-medial. O-arm images were obtained at three dosage settings: LD (kVp120/mAs125-lowest manufacturer recommended), very-low dose (VLD) (kVp120/mAs63), and ULD (kVp120/mAs39). Computed tomography (CT) scan was performed using institution's LD protocol (kVp100/mAs50) and gross dissection to identify screw positions. RESULTS: LD, VLD, ULD, and CT for identifying "IN" screws relative to gross dissection had, a mean (standard deviation) sensitivity of 84.2% (±5.7), specificity of 76.1% (±9.3), and accuracy of 79.9% (±3.1) from all three observers. Across the three observers, the interobserver agreement was 0.67 (0.61-0.72) for LD, 0.74 (0.69-0.79) for VLD, 0.61 (0.56-0.66) for ULD, and 0.79 (0.74-0.84) for CT. Effective doses of radiation (mSV) for LD O-arm scan was 2.16, VLD 1.08, ULD 0.68, and our LD CT protocol was 1.05. CONCLUSION: Accuracy of pedicle screw placement is similar for O-arm at all doses and CT compared to gross dissection. Interobserver reliability was substantial for VLD and CT. Approximately 30% of medial screw breaches are, however, misclassified. ULD and VLDs can be used for intraoperative navigation and evaluation purposes within these limitations. LEVEL OF EVIDENCE: N/A.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Sarwahi V, Payares M, Wendolowski S, et al. Low-Dose Radiation 3D Intraoperative Imaging: How Low Can We Go? An O-Arm, CT Scan, Cadaveric Study. Spine (Phila Pa 1976). 2017. PMID: 28296816. doi:10.1097/BRS.0000000000002154

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。