全膝关节置换术中非骨水泥金属背衬钽髌骨假体中期随访骨折率高
回顾性分析2006年9月至2009年4月间29例患者30膝行非骨水泥全膝关节置换并采用非骨水泥金属背衬钽髌骨假体,平均影像随访5.5年,发现6例髌骨假体骨折,全队列骨折率20%,正位片可见髌骨的17膝中骨折率35%,均为横行骨折,无假体明显松动;作者结论提示中期随访组件骨折率至少20%,许多骨折无症状但可能影响远期翻修率。
要点
- 非骨水泥金属背衬钽髌骨假体中期随访组件骨折率至少20%。
- 正位X线片上可见髌骨的17膝中骨折率达35%。
- 全部骨折均为横行骨折,未发现假体明显松动。
核心结论
- 作者认为中期随访组件骨折率至少为20%,许多髌骨组件骨折无症状但可能影响远期翻修率。
研究设计与样本
- 回顾性连续系列研究,纳入2006年9月至2009年4月间29例患者30膝行非骨水泥全膝关节置换并采用非骨水泥金属背衬钽髌骨假体,要求至少2年影像随访。
主要发现
- 平均年龄59.1岁,平均体质指数31.9 kg/m2,平均术后影像随访时间5.5年。
- 共发现6例髌骨组件骨折,全队列骨折率20%,正位X线片上可见髌骨的17膝中骨折率35%,全部骨折均为横行骨折。
- 未发现髌骨组件明显松动;组件骨折患者中2例因不稳行翻修,1例因感染行翻修。
关键数值与推荐
- 全队列30膝中6例髌骨组件骨折,骨折率20%。
- 正位X线片可见髌骨的17膝中6例骨折,骨折率35%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is interest in uncemented total knee arthroplasty due to the hope for long-term biologic fixation, but limited data are available regarding uncemented tantalum patellar components. The purpose of this study was to evaluate the radiographic outcomes of uncemented tantalum patellar implants at midterm follow-up. METHODS: We retrospectively reviewed a consecutive series of 30 knees in 29 patients who underwent cementless total knee arthroplasty with an uncemented metal-backed tantalum patella between September 2006 and April 2009. Patients were required to have a minimum radiographic follow-up of 2 years. Anteroposterior and lateral radiographs of the knee were evaluated for signs of implant fracture or gross loosening. Clinical follow-up was obtained by reviewing each patient's most recent orthopedic record. RESULTS: Thirty knees in 29 patients met inclusion criteria. The mean age of the cohort was 59.1 years with a mean body mass index of 31.9 kg/m2. Mean postoperative radiographic follow-up time was 5.5 years. Six fractures of the patellar component were noted. This represented a fracture rate of 20% among the entire cohort and 35% among the 17 knees with visible patellae on anteroposterior radiograph. All fractures had a transverse pattern. No gross patellar component loosening was noted. Among patients with component fractures, 2 required revisions for instability and 1 revision was for infection. CONCLUSION: Our results suggest a minimum 20% rate of component fracture at midterm follow-up. Although many of these patellar component fractures were asymptomatic, they have the potential to impact revision rates in the longer term.
引用
- Chan JY, Giori NJ. Uncemented Metal-Backed Tantalum Patellar Components in Total Knee Arthroplasty Have a High Fracture Rate at Midterm Follow-Up. J Arthroplasty. 2017. PMID: 28341281. doi:10.1016/j.arth.2017.02.062
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。