保留关节软骨的全股骨头同种异体骨打压植骨技术行八例翻修髋关节置换的生存率分析
回顾性分析80例采用保留关节软骨的嵌压碎骨植骨与骨水泥杯行髋臼翻修的病例,平均随访6.5年(范围1-13年),63个髋臼(85.1%)影像学稳定,Kaplan-Meier生存率95.9%(95%CI 5.6-7.5)。作者认为中期结果有前景,在新鲜冷冻同种异体骨供应和手术时间有限时,使用带关节软骨的全股骨头安全有效。
要点
- 80例髋臼翻修中63个髋臼(85.1%)影像学稳定,8个(10.8%)影像学松动,3个(4.1%)出现移位。
- 51例(68.9%)显示良好骨小梁重塑(3级),20例(27%)骨小梁整合(2级),3例(4.1%)整合差。
- 平均随访6.5年因任何原因翻修杯的Kaplan-Meier生存率为95.9%(95%CI 5.6-7.5)。
核心结论
- 作者认为该技术的中期结果有前景,尤其在新鲜冷冻同种异体骨供应和手术时间有限时,使用带关节软骨的全股骨头安全有效。
研究设计与样本
- 回顾性研究80例采用保留关节软骨的嵌压碎骨植骨与骨水泥杯行髋臼翻修的病例,随访中失访6例,平均随访6.5年(范围1-13年)。
主要发现
- 63个髋臼(85.1%)影像学稳定(0、1、2型界限),8个(10.8%)影像学松动(3型),3个(4.1%)出现移位。
- 51例(68.9%)显示良好骨小梁重塑(3级),20例(27%)骨小梁整合(2级),3例(4.1%)同种异体骨整合差。
- 术前平均髋关节评分为43分,术后为28分。
- 6例(8.1%)翻修植入物周围出现异位骨化,2例(2.7%)发生假体周围骨折,4例(5.4%)发生脱位。
- 平均6.5年因任何原因翻修杯的Kaplan-Meier生存率为95.9%(95%CI 5.6-7.5)。
临床怎么用
- 作者认为该技术中期结果有前景,尤其在新鲜冷冻同种异体骨供应和手术时间有限时,使用带关节软骨的全股骨头安全有效。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Acetabular impaction bone grafting aims to restore anatomy in hip revision surgery. This is an effective but expensive and time-consuming technique. Usually, the articular cartilage is removed from the femoral head allograft. We aimed to reproduce the same results retaining the cartilage of the allograft. METHODS: Eighty acetabular revisions using impacted morselized bone graft retaining the articular cartilage and a cemented cup were studied retrospectively. Six were lost during follow-up. The mean follow-up was 6.5 years (range 1-13). Clinical and radiological assessment was made using the Oxford Hip Score, Hodgkinson's criteria for socket loosening, and the Gie classification for evaluation of allograft incorporation. RESULTS: Sixty-three sockets (85.1%) were considered radiologically stable (type 0, 1, and 2 demarcations), 8 (10.8%) were radiologically loose (type 3), and 3 (4.1%) presented with migration. Fifty-one (68.9%) cases showed good trabecular remodeling (grade 3), 20 (27%) showed trabecular incorporation (grade 2), and 3 (4.1%) showed poor allograft incorporation. Mean preoperative hip score was 43 and postoperative score was 28. Six (8.1%) cases presented heterotopic ossification around the revised implants, 2 patients (2.7%) had periprosthetic fractures, and 4 (5.4%) had dislocations. The Kaplan-Meier survivorship at a mean of 6.5 years with revision of the cup for any reason was 95.9% (95% confidence interval 5.6-7.5). CONCLUSION: The mid-term results of our technique are promising. Particularly when the supply of fresh-frozen allografts and surgical time is limited, using whole femoral head with articular cartilage is both safe and effective.
引用
- Fadulelmola A, Drampalos E, Hodgkinson J, et al. Survivorship Analysis of Eighty Revised Hip Arthroplasties With the Impaction Grafting Technique Using Whole Femoral Head Allografts With the Articular Cartilage. J Arthroplasty. 2017. PMID: 28202208. doi:10.1016/j.arth.2017.01.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。