多次翻修全髋关节置换术中骨水泥套内骨水泥股骨假体翻修:至少五年随访结果
研究回顾了24例(51次手术)同一股骨假体接受多次骨水泥套内骨水泥翻修的患者,平均随访81.7个月。末次随访时OHS(p=0.041)、HHS(p=0.019)和MDP(p=0.042)评分显著改善,无因无菌性松动行股骨柄翻修。以所有原因为终点的股骨假体五年生存率91.9%(95%CI 71.5-97.9),十年生存率91.7%(95%CI 70-97)。作者认为骨水泥套内骨水泥翻修是多次翻修固定良好的骨水泥股骨假体的可行技术。
要点
- 24例患者共51次骨水泥套内骨水泥翻修,平均随访81.7个月。
- 末次随访OHS、HHS、MDP评分均显著改善(p值分别为0.041、0.019、0.042)。
- 股骨假体五年生存率91.9%,十年生存率91.7%,无因无菌性松动行股骨柄翻修。
核心结论
- 骨水泥套内骨水泥翻修是多次翻修全髋关节置换术中处理固定良好的骨水泥股骨假体的可行技术,至少五年随访结果支持。
研究设计与样本
- 回顾性连续系列研究,纳入24例(10男,14女)同一股骨假体接受不止一次骨水泥套内骨水泥翻修的患者,共51次手术,末次随访平均年龄67.5岁(36至92岁)。
主要发现
- 平均随访81.7个月(64至240个月),共行41次单纯髋臼翻修(股骨柄取出以便显露髋臼)、6次因两组件均松动行翻修、2次单纯股骨柄翻修,每例患者至少接受过两次翻修。
- 末次随访时OHS评分显著改善(p=0.041),HHS评分显著改善(p=0.019),MDP评分显著改善(p=0.042)。
- 无因无菌性松动行股骨柄翻修。
- 以所有原因为终点的股骨假体生存率:五年91.9%(95%CI 71.5至97.9),十年91.7%(95%CI 70至97),风险人数13。
临床怎么用
- 作者认为骨水泥套内骨水泥翻修是多次翻修全髋关节置换术中处理固定良好的骨水泥股骨假体的可行技术。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: We present the clinical and radiological results at a minimum follow-up of five years for patients who have undergone multiple cement-in-cement revisions of their femoral component at revision total hip arthroplasty (THA). PATIENTS AND METHODS: We reviewed the outcome on a consecutive series of 24 patients (10 men, 14 women) (51 procedures) who underwent more than one cement-in-cement revision of the same femoral component. The mean age of the patients was 67.5 years (36 to 92) at final follow-up. Function was assessed using the original Harris hip score (HHS), Oxford Hip Score (OHS) and the Merle D'Aubigné Postel score (MDP). RESULTS: The mean length of follow-up was 81.7 months (64 to 240). A total of 41 isolated acetabular revisions were performed in which stem removal facilitated access to the acetabulum, six revisions were conducted for loosening of both components and two were isolated stem revisions (each of these patients had undergone at least two revisions). There was significant improvement in the OHS (p = 0.041), HHS (p = 0.019) and MDP (p = 0.042) scores at final follow-up There were no stem revisions for aseptic loosening. Survival of the femoral component was 91.9% (95% confidence intervals (CI) 71.5 to 97.9) at five years and 91.7% (95% CI 70 to 97) at ten years (number at risk 13), with stem revision for all causes as the endpoint. CONCLUSION: Cement-in-cement revision is a viable technique for performing multiple revisions of the well cemented femoral component during revision total hip arthroplasty at a minimum of five years follow-up. Cite this article: Bone Joint J 2017;99-B:199-203.
引用
- Sandiford NA, Jameson SS, Wilson MJ, et al. Cement-in-cement femoral component revision in the multiply revised total hip arthroplasty: results with a minimum follow-up of five years. Bone Joint J. 2017. PMID: 28148661. doi:10.1302/0301-620X.99B2.BJJ-2016-0076.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。