英文版遗忘关节评分-12在英国人群全髋与全膝关节置换术结局评估中的验证
研究纳入2014年1月至8月接受手术的205例全髋关节置换术(THA)和231例全膝关节置换术(TKA)患者,术前及术后6、12个月采用遗忘关节评分-12(FJS-12)与牛津髋/膝关节评分(OHS/OKS)评估。结果显示FJS-12在TKA和THA中均具有高内部一致性(Cronbach α分别为0.97和0.98)及与牛津评分的高收敛效度(r分别为0.85和0.79),1年随访天花板效应低(TKA 3.9%、THA 8.8%)。结论认为FJS-12在TKA和THA患者中具有较好的测量性能。
要点
- FJS-12在TKA和THA中内部一致性高(Cronbach α=0.97和0.98)。
- FJS-12与牛津评分收敛效度高(TKA r=0.85,THA r=0.79)。
- 1年随访天花板效应低(TKA 3.9%,THA 8.8%)。
核心结论
- FJS-12在TKA和THA患者中在效度、内部一致性和对变化的敏感性方面具有较强的测量性能。
- 低天花板效应和良好的相对效度允许对全关节置换术后长期结局进行监测,尤其是在表现良好的组中。
研究设计与样本
- 前瞻性收集2014年1月至8月期间接受手术的205例THA和231例TKA患者数据。
- 术前及术后6个月和12个月采用FJS-12与牛津髋/膝关节评分(OHS、OKS)评估结局。
- 测定内部一致性、收敛效度、效应量、相对效度和天花板效应。
主要发现
- FJS-12在TKA中Cronbach α=0.97,在THA中Cronbach α=0.98。
- FJS-12与牛津评分的收敛效度在TKA中r=0.85,在THA中r=0.79。
- 从6个月到12个月,THA患者FJS-12的变化效应量d=0.21,OHS的效应量d=-0.03。
- 1年随访时FJS-12天花板效应低,仅3.9%(TKA)和8.8%(THA)的患者达到最佳可能评分。
关键数值与推荐
- FJS-12内部一致性:TKA Cronbach α=0.97,THA Cronbach α=0.98。
- FJS-12与牛津评分收敛效度:TKA r=0.85,THA r=0.79。
- THA患者6至12个月FJS-12效应量d=0.21,OHS效应量d=-0.03。
- 1年随访FJS-12天花板效应:TKA 3.9%,THA 8.8%。
临床怎么用
- FJS-12可用于监测TKA和THA术后长期结局,尤其适用于表现良好的组。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To validate the English language Forgotten Joint Score-12 (FJS-12) as a tool to evaluate the outcome of hip and knee arthroplasty in a United Kingdom population. PATIENTS AND METHODS: All patients undergoing surgery between January and August 2014 were eligible for inclusion. Prospective data were collected from 205 patients undergoing total hip arthroplasty (THA) and 231 patients undergoing total knee arthroplasty (TKA). Outcomes were assessed with the FJS-12 and the Oxford Hip and Knee Scores (OHS, OKS) pre-operatively, then at six and 12 months post-operatively. Internal consistency, convergent validity, effect size, relative validity and ceiling effects were determined. RESULTS: Data for the TKA and THA patients showed high internal consistency for the FJS-12 (Cronbach α = 0.97 in TKAs, 0.98 in THAs). Convergent validity with the Oxford Scores was high (r = 0.85 in TKAs, r = 0.79 for THAs). From six to 12 months, the change was higher for the FJS-12 than for the OHS in THA patients (effect size d = 0.21 versus -0.03). Ceiling effects at one-year follow-up were low for the FJS-12 with just 3.9% (TKA) and 8.8% (THA) of patients achieving the best possible score. CONCLUSION: The FJS-12 has strong measurement properties in terms of validity, internal consistency and sensitivity to change in TKA and THA patients. Low ceiling effects and good relative validity allow the monitoring of longer term outcomes, particularly in well-performing groups after total joint arthroplasty. Cite this article: Bone Joint J 2017;99-B:218-24.
引用
- Hamilton DF, Loth FL, Giesinger JM, et al. Validation of the English language Forgotten Joint Score-12 as an outcome measure for total hip and knee arthroplasty in a British population. Bone Joint J. 2017. PMID: 28148664. doi:10.1302/0301-620X.99B2.BJJ-2016-0606.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。