全髋关节置换术后正常金属离子水平是多少?四种摩擦界面的血清学分析
研究测量了80例功能良好单侧全髋关节置换患者的血清钴、铬、钛水平,比较陶瓷对陶瓷、陶瓷对聚乙烯、金属对聚乙烯和双动四组摩擦界面,发现四组间血清钴和铬无显著差异,金属股骨头组血清钴显著高于陶瓷股骨头组,金属离子水平与患者报告结局无相关性。
要点
- 四种摩擦界面组间血清钴和铬水平无显著差异(P=.0609和P=.1577)。
- 金属股骨头组血清钴显著高于陶瓷股骨头组(1.05 mg/L±1.25 vs 0.59 mg/L±0.24;P=.0411)。
- 金属离子水平与患者报告结局评分无相关性。
核心结论
- 功能良好的现代摩擦界面全髋关节置换术后血清金属离子水平无差异。
- 金属股骨头与陶瓷股骨头相比血清钴水平显著更高,需进一步研究。
- 金属离子水平与患者报告结局指标无相关性。
研究设计与样本
- 研究纳入80例功能良好单侧全髋关节置换的非连续患者,比较陶瓷对陶瓷、陶瓷对聚乙烯、金属对聚乙烯和双动四种摩擦界面。
- 比较各组术前和最近一次加州大学洛杉矶分校(UCLA)和西安大略和麦克马斯特大学骨关节炎指数(WOMAC)评分。
主要发现
- 四种摩擦界面组间血清钴和铬水平无显著差异(P=.0609和P=.1577)。
- 金属股骨头组(金属对聚乙烯、模块化双动(Stryker Orthopedics, Mahwah, NJ)[金属])血清钴水平显著高于陶瓷股骨头组(陶瓷对陶瓷、陶瓷对聚乙烯、模块化双动[陶瓷])(1.05 mg/L±1.25 vs 0.59 mg/L±0.24;P=.0411)。
- Spearman系数未发现金属离子水平与患者报告结局评分之间存在相关性。
临床怎么用
- 原文未据此给出推荐。
局限性
- 金属股骨头与陶瓷股骨头相比血清钴水平显著更高,需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The recent experiences with adverse local tissue reactions have highlighted the need to establish what are normal serum levels of cobalt (Co), chromium (Cr), and titanium (Ti) after hip arthroplasty. METHODS: Serum Co, Cr, and Ti levels were measured in 80 nonconsecutive patients with well-functioning unilateral total hip arthroplasty and compared among 4 bearing surfaces: ceramic-on-ceramic (CoC); ceramic-on-polyethylene (CoP); metal-on-polyethylene (MoP), and dual mobility (DM). The preoperative and most recent University of California, Los Angeles (UCLA) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were compared among the different bearing surfaces. RESULTS: No significant difference was found among serum Co and Cr levels between the 4 bearing surface groups (P = .0609 and P = .1577). Secondary analysis comparing metal and ceramic femoral heads demonstrated that the metal group (MoP, modular dual mobility (Stryker Orthopedics, Mahwah, NJ) [metal]) had significant higher serum Co levels compared with the ceramic group (CoC, CoP, MDM [ceramic]) (1.05 mg/L ± 1.25 vs 0.59 mg/L ± 0.24; P = .0411). Spearman coefficient identified no correlation between metal ion levels and patient-reported outcome scores. CONCLUSION: No serum metal ion level differences were found among well-functioning total hip arthroplasty with modern bearing couples. Significantly higher serum Co levels were seen when comparing metal vs ceramic femoral heads in this study and warrants further investigation. Metal ion levels did not correlate with patient-reported outcome measures.
引用
- Barlow BT, Ortiz PA, Boles JW, et al. What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces. J Arthroplasty. 2016. PMID: 28190644. doi:10.1016/j.arth.2016.11.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。