单半径后稳定型全膝关节置换术中间隙平衡与测量截骨技术的接触运动学差异
研究将24膝(23例)随机分配至测量截骨(MR)或间隙平衡(GB)组,使用同一单半径后稳定型假体,术后1年进行双平面影像学检查。两组髁部抬起的频率无差异(P=.41),MR组内侧髁接触更偏后(P<.01)、外侧髁接触更偏前(P<.01),运动幅度和临床评分无差异。结论认为对于该假体系统,GB与MR产生相似的运动学和患者报告结果。
要点
- 两组髁部抬起频率无差异(P=.41)
- MR组内侧髁接触更偏后、外侧髁接触更偏前(均P<.01)
- 两组内外侧运动幅度及临床评分无差异
核心结论
- 对于该特定假体系统,间隙平衡(GB)与测量截骨(MR)似乎产生相似的運動学和患者报告结果。
研究设计与样本
- 研究纳入24膝(23例患者),在转诊时随机分配至执行MR或GB全膝关节置换术的外科医生,使用同一单半径后稳定型假体(每组12膝)。
- 术后1年患者在0°、20°、40°和60°屈曲位接受双平面放射学成像,测量髁部抬起、接触位置及每侧髁的移动幅度,并收集术前和术后临床结局评分。
主要发现
- 两组间髁部抬起频率无差异(P=.41)。
- MR组在整个屈曲过程中内侧髁接触更偏后(P<.01),外侧髁接触更偏前(P<.01)。
- 两组运动模式相似,内侧移动幅度(P=.48)和外侧移动幅度(P=.44)相似,且MR组(P=.48)和GB组(P=.73)内外侧髁移动幅度相等。
- 两组临床结局评分无差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Measured resection (MR) and gap balancing (GB) are common surgical techniques for total knee arthroplasty (TKA). Controversy has arisen as each conceptually differs in how the knee is balanced through bone and soft tissue management. The objective of the present study was to compare both the frequency of condylar liftoff and the location of femorotibial contact from extension through midflexion between patients undergoing GB or MR TKA. METHODS: A total of 24 knees (23 patients) were randomly assigned at referral to either a surgeon performing MR or GB TKA with the same single radius, posterior-stabilized implant (12 per cohort). At 1-year postoperation, patients underwent biplanar radiographic imaging at 0°, 20°, 40°, and 60° of flexion. Condylar liftoff, contact location, and magnitude of excursion on each condyle were measured. Preoperative and postoperative clinical outcome scores were also collected. RESULTS: There was no difference (P = .41) in the frequency of liftoff between cohorts. The MR cohort had more posterior contact on the medial condyle (P < .01) and more anterior contact on the lateral condyle (P < .01) throughout flexion. Motion patterns were similar between cohorts, with similar medial (P = .48) and lateral (P = .44) excursion, which was equal in magnitude between condyles for both MR (P = .48) and GB (P = .73). There was no difference in clinical outcome scores between groups. CONCLUSION: For this particular implant system, GB and MR appear to produce similar kinematic and patient-reported outcome results.
引用
- Teeter MG, Perry KI, Yuan X, et al. Contact Kinematic Differences Between Gap Balanced vs Measured Resection Techniques for Single Radius Posterior-Stabilized Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28209275. doi:10.1016/j.arth.2016.12.054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。