文献速递关节外科

缝合与止血带对导航全膝关节置换术中运动学的影响

Effects of Suture and Tourniquet on Intraoperative Kinematics in Navigated Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2017-01-30

研究纳入20例内翻型膝骨关节炎行初次后稳定型全膝关节置换术并使用CT导航的患者,术中测量最大伸直至最大屈曲的胫股运动学3次:缝合前(止血带充气)、缝合后(止血带充气)、止血带松开后。结果显示缝合与止血带对运动学影响极小,术中运动学可有效评估术后被动运动学状态。

要点

  • 内侧间室:3次测量伸直间隙无显著差异,测量1屈曲间隙显著大于另两次测量。
  • 外侧间室:所有测量中伸直与屈曲间隙均无显著差异。
  • 胫股旋转角度在3次测量间无显著差异。

核心结论

  • 缝合与止血带对术中运动学的影响极小,术中运动学可有效评估术后被动运动学状态。

研究设计与样本

  • 研究纳入20例内翻型膝骨关节炎患者,行初次后稳定型全膝关节置换术并使用基于计算机断层扫描(CT)的导航。

主要发现

  • 内侧间室伸直间隙在3次测量间无显著差异,测量1(缝合前、止血带充气)的屈曲间隙显著大于测量2(缝合后、止血带充气)和测量3(止血带松开后)。
  • 外侧间室伸直间隙与屈曲间隙在所有测量中均无显著差异。
  • 测量1中股骨相对于胫骨在屈曲10°和20°时显著更靠前,与缝合后的另两次测量相比。
  • 胫股旋转角度在3次测量间无显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To investigate the effects of suture (soft tissue closure) and air tourniquet use on intraoperative kinematics in navigated total knee arthroplasty. METHODS: The study included 20 patients with varus-type knee osteoarthritis who underwent primary posterior-stabilized total knee arthroplasty using computed tomography (CT)-based navigation. Intraoperative tibiofemoral kinematics from maximum extension to maximum flexion were measured using the computed tomography-based navigation. The measurements were performed 3 times as follows: measurement 1: before suture (tourniquet on), measurement 2: after suture (tourniquet on), and measurement 3: after tourniquet removal. Details of kinematics including knee joint gap, tibiofemoral rotational angles, and anteroposterior (AP) distance between the femur and tibia were compared among the 3 measurements and statistically evaluated. RESULTS: On the medial side, there was no significant difference among the 3 measurements in the extension gap, but measurement 1 showed a significantly larger flexion gap compared with the other 2 measurements. On the lateral side, there was no significant difference between the extension and flexion gaps in all measurements. The anteroposterior distance in measurement 1 showed that the femur was positioned significantly more anterior to the tibia at 10° and 20° of flexion compared with the other 2 measurements after suture. There was no significant difference among the 3 measurements in the tibiofemoral rotation angles. CONCLUSION: These results found that the effect of suture and tourniquet was minimal, and that intraoperative kinematics can effectively evaluate postoperative passive kinematic conditions.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Tsubosaka M, Ishida K, Sasaki H, et al. Effects of Suture and Tourniquet on Intraoperative Kinematics in Navigated Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28233604. doi:10.1016/j.arth.2017.01.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。