文献速递关节外科

新一代非骨水泥全膝关节置换术的结局:珠状过磷酸钙涂层与高孔隙钛涂层假体的比较

Outcomes of Newer Generation Cementless Total Knee Arthroplasty: Beaded Periapatite-Coated vs Highly Porous Titanium-Coated Implants.
PubMed 文献 · J Arthroplasty · 2017-02-03

本研究比较了805例珠状过磷酸钙(PA)涂层与219例高孔隙钛涂层非骨水泥全膝关节置换术(TKA)假体的结局,平均随访4.4年。两组假体生存率均为99.5%,膝关节协会评分(KSS)疼痛与功能、活动度改善、并发症率及翻修数均无显著差异。作者认为两种假体临床结局良好,未来需多中心大规模临床与成本效益研究以确定优劣。

要点

  • 珠状PA涂层组假体生存率99.5%(95%CI 97.9%-99.9%),高孔隙钛涂层组99.5%(95%CI 92.7%-99.9%)。
  • 两组KSS疼痛与功能评分无显著差异,屈伸活动度改善相似。
  • 并发症率2.2% vs 2.3%(P=.274),翻修数6例(0.8%)vs 2例(0.2%)(P=.936),均无显著差异。

核心结论

  • 两种非骨水泥TKA假体均显示出良好的临床和患者报告结局。
  • 未来需多中心大规模临床与成本效益研究以确定一种非骨水泥假体是否优于另一种。

研究设计与样本

  • 比较性研究,纳入805例珠状PA涂层胫骨和髌骨假体TKA(PA组,平均年龄67岁,范围41-86岁)与219例高孔隙钛涂层胫骨和髌骨假体TKA(平均年龄66岁,范围34-88岁)。
  • 平均随访4.4年(范围2-9年;中位数4年),采用Kaplan-Meier曲线计算假体生存率,使用Student t检验和卡方检验。
  • 影像学评估采用膝关节协会影像学评估与评分系统。

主要发现

  • 珠状PA涂层组全因假体生存率为99.5%(95%CI 97.9%-99.9%),高孔隙钛涂层组为99.5%(95%CI 92.7%-99.9%)。
  • 两组KSS疼痛与功能评分无显著差异,屈曲和伸展改善相似。
  • 总体并发症率2.2% vs 2.3%(P=.274),翻修数6例(0.8%)vs 2例(0.2%)(P=.936),两组相似。
  • 排除无菌性和感染性失败后,影像学评估未见进行性透亮线或骨溶解。

关键数值与推荐

  • 全因假体生存率:珠状PA涂层组99.5%(95%CI 97.9%-99.9%),高孔隙钛涂层组99.5%(95%CI 92.7%-99.9%)。
  • 并发症率:PA组2.2% vs 高孔隙钛涂层组2.3%(P=.274)。
  • 翻修数:PA组6例(0.8%)vs 高孔隙钛涂层组2例(0.2%)(P=.936)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Newer generation cementless total knee arthroplasty (TKA) designs are available and have novel implant coatings. We evaluated and compared beaded periapatite (PA)-coated vs highly porous titanium-coated cementless TKAs. Specifically, we compared: (1) survivorship, (2) Knee Society Scores (KSSs) and range of motion, (3) complications, and (4) radiographic findings. METHODS: There were 805 TKAs with beaded PA-coated tibial and patellar components (PA group; mean age 67 years; range 41-86 years), and 219 TKAs with highly porous titanium-coated tibial and patella components (mean age 66 years; range 34-88 years). Mean follow-up was 4.4 years (range 2-9 years; median 4 years). Implant survivorship was calculated using Kaplan-Meier curves. Student t-tests and chi-square tests were used as appropriate. Radiographic evaluation was performed using Knee Society Roentgenographic Evaluation and Scoring System. RESULTS: All-cause implant survivorship in beaded PA-coated group was 99.5% (95% CI, 97.9%-99.9%) and 99.5% (95% CI, 92.7%-99.9%) in highly porous titanium-coated group. There were no significant differences in the KSS for pain and function. Improvement in flexion and extension was similar in the 2 groups. Overall, complication rate (2.2% vs 2.3%; P = .274) and number of revisions (6 [0.8%] vs 2 [0.2%]; P = .936) were similar in the 2 groups. Excluding the aseptic and septic failures, there were no progressive radiolucencies or osteolysis on radiographic evaluation. CONCLUSION: This study has shown good clinical and patient-reported outcomes of cementless TKA for both implants. Future multicenter large scale clinical and cost-effectiveness studies are needed to determine the superiority of one cementless implant type over the other.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Harwin SF, Patel NK, Chughtai M, et al. Outcomes of Newer Generation Cementless Total Knee Arthroplasty: Beaded Periapatite-Coated vs Highly Porous Titanium-Coated Implants. J Arthroplasty. 2017. PMID: 28237217. doi:10.1016/j.arth.2017.01.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。