全髋关节置换术患者功能性骨盆倾斜的变化
该研究术前测量了1517例全髋关节置换术(THA)患者在仰卧位、站立位和屈膝坐位三种功能体位下的骨盆倾斜,发现不同体位间骨盆倾斜存在个体差异,17%患者矢状面骨盆旋转可导致髋臼假体功能位置不良,计入±5°术中放置误差后风险扩展至51%。
要点
- 仰卧位、站立位、屈膝坐位平均骨盆倾斜分别为4.2°、-1.3°、0.6°(前倾为正值)。
- 仰卧位到站立位平均矢状面骨盆旋转为-5.5°,仰卧位到屈膝坐位为-3.7°。
- 17%患者矢状面骨盆旋转可致髋臼假体功能位置不良,计入±5°术中误差后为51%。
核心结论
- 仰卧位规划和测量髋臼假体预期位置可能无法预测其在功能活动中方向的临床显著变化,原因是个体骨盆运动学差异。
- 最佳方向因患者而异,术前需要评估功能性骨盆倾斜。
研究设计与样本
- 术前测量1517例接受全髋关节置换术(THA)患者在仰卧位、站立位和屈膝坐位三种功能体位下的骨盆倾斜。
- 仰卧位骨盆倾斜通过CT扫描测量,站立位和屈膝坐位骨盆倾斜通过标准化侧位X线片测量。
- 前倾骨盆倾斜赋为正值。
主要发现
- 平均骨盆倾斜在仰卧位为4.2°(范围-20.5°至24.5°),站立位为-1.3°(范围-30.2°至27.9°),屈膝坐位为0.6°(范围-42.0°至41.3°)。
- 平均矢状面骨盆旋转从仰卧位到站立位为-5.5°(范围-21.8°至8.4°),从仰卧位到屈膝坐位为-3.7°(范围-48.3°至38.6°),从站立位到屈膝坐位为1.8°(范围-51.8°至39.5°)。
- 259例患者(17%)的矢状面骨盆旋转程度可导致髋臼假体功能位置不良。
- 计入±5°术中放置误差后,该风险扩展至51%的患者。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The pelvis rotates in the sagittal plane during daily activities. These rotations have a direct effect on the functional orientation of the acetabulum. The aim of this study was to quantify changes in pelvic tilt between different functional positions. PATIENTS AND METHODS: Pre-operatively, pelvic tilt was measured in 1517 patients undergoing total hip arthroplasty (THA) in three functional positions - supine, standing and flexed seated (the moment when patients initiate rising from a seated position). Supine pelvic tilt was measured from CT scans, standing and flexed seated pelvic tilts were measured from standardised lateral radiographs. Anterior pelvic tilt was assigned a positive value. RESULTS: The mean pelvic tilt was 4.2° (-20.5° to 24.5°), -1.3° (-30.2° to 27.9°) and 0.6° (-42.0° to 41.3°) in the three positions, respectively. The mean sagittal pelvic rotation from supine to standing was -5.5° (-21.8° to 8.4°), from supine to flexed seated was -3.7° (-48.3° to 38.6°) and from standing to flexed seated was 1.8° (-51.8° to 39.5°). In 259 patients (17%), the extent of sagittal pelvic rotation could lead to functional malorientation of the acetabular component. Factoring in an intra-operative delivery error of ± 5° extends this risk to 51% of patients. CONCLUSION: Planning and measurement of the intended position of the acetabular component in the supine position may fail to predict clinically significant changes in its orientation during functional activities, as a consequence of individual pelvic kinematics. Optimal orientation is patient-specific and requires an evaluation of functional pelvic tilt pre-operatively. Cite this article: Bone Joint J 2017;99-B:184-91.
引用
- Pierrepont J, Hawdon G, Miles BP, et al. Variation in functional pelvic tilt in patients undergoing total hip arthroplasty. Bone Joint J. 2017. PMID: 28148659. doi:10.1302/0301-620X.99B2.BJJ-2016-0098.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。