移动平台翻修全膝关节置换术的中期临床与影像学结果
回顾性分析2个中心2006至2010年间316例连续移动平台翻修全膝关节置换术,平均随访59.88个月,膝关节协会评分和活动度均较术前改善(P < .01),8例需再次植入物翻修,未观察到平台相关并发症。
要点
- 移动平台翻修全膝关节置换术后中期膝关节协会评分和活动度较术前显著改善(P < .01)。
- 平均随访59.88个月,316例中8例需再次植入物翻修,未发生平台不稳定或脱位。
- 作者认为需更长期随访评估移动平台相较固定平台在减少聚乙烯磨损等方面的潜在优势。
核心结论
- 使用移动平台翻修假体行翻修全膝关节置换术的中期临床和影像学结果良好,未发生平台不稳定或脱位。
研究设计与样本
- 回顾性综述2个中心2006至2010年间连续进行的316例移动平台翻修全膝关节置换术,其中女性183例、男性133例,平均年龄66岁。
主要发现
- 患者随访至少24个月,中位随访59.88个月(范围24–121.2个月)。
- 平均膝关节协会膝关节评分从术前40.8分增至术后80分,功能评分从术前47.9分增至术后70.3分(P < .01)。
- 平均膝关节屈曲度从术前105.6°改善至术后117.4°(P < .01)。
- 8例患者需再次植入物翻修,未观察到平台相关并发症(即不稳定或脱位)。
局限性
- 作者指出需要更长期随访以评估移动平台相较固定平台翻修假体在减少聚乙烯磨损、降低固定界面应力传递和降低聚乙烯柱应力方面的潜在优势。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Constrained implants are frequently required in revision total knee arthroplasty (TKA) and are associated with an increase in aseptic component loosening and damage or wear to the constraining mechanisms, compared with primary TKA. The purpose of the following study was to evaluate the midterm clinical and radiographic results including the incidence of bearing complications in a group of patients undergoing revision TKA using mobile-bearing revision TKA implants. METHODS: We retrospectively reviewed 316 consecutive mobile-bearing revision TKAs performed at 2 centers between 2006 and 2010. There were 183 women and 133 men with a mean age of 66 years. The patients were evaluated clinically using the Knee Society scores. A radiographic analysis was performed. Bearing specific complications (ie, instability or dislocation) were recorded. RESULTS: Patients were followed-up for a minimum of 24 months and a median of 59.88 months (range 24-121.2). The average Knee Society knee score and function scores increased from 40.8 and 47.9 points preoperatively to 80 points and 70.3 points, respectively (P < .01). The average knee flexion improved from 105.6° preoperatively to 117.4° postoperatively (P < .01). Eight patients required subsequent implant revision. No cases of bearing complications were observed. CONCLUSION: Revision TKA using mobile-bearing revision components demonstrated favorable midterm clinical and radiographic results with no occurrence of bearing instability or dislocation. Longer follow-up is required to evaluate for potential advantages of mobile-bearings over fixed-bearing revision components in terms of polyethylene wear reduction, reduced stress transmission across fixation interfaces, and reduced stress on the polyethylene post.
引用
- Kim RH, Martin JR, Dennis DA, et al. Midterm Clinical and Radiographic Results of Mobile-Bearing Revision Total Knee Arthroplasty. J Arthroplasty. 2017. PMID: 28209272. doi:10.1016/j.arth.2017.01.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。