基于计算机断层扫描的三维测量:后路三柱截骨术治疗严重僵硬性脊柱侧凸后脊柱短缩距离

Computed Tomography Based Three-dimensional Measurements of Spine Shortening Distance After Posterior Three-column Osteotomies for the Treatment of Severe and Stiff Scoliosis.
PubMed 文献 · Spine (Phila Pa 1976) · 2017-01-01

回顾性研究纳入52例严重僵硬性脊柱侧凸患者,行后路三柱截骨术(9例扩大椎弓根截骨、43例后路全椎体切除)。三维模型测得的脊柱短缩距离(27.8 mm)小于术中测量值(32.8 mm)(P<0.05),两者强相关(r=0.82);中央椎管短缩距离显著短于凸侧脊柱短缩距离(P<0.05)。

要点

  • 三维模型测得的脊柱短缩距离为27.8 mm,术中测量为32.8 mm,两者强相关(r=0.82)。
  • 中央椎管短缩距离显著短于凸侧脊柱短缩距离(P<0.05)。
  • 前柱支撑植骨组的凸侧脊柱短缩距离和中央椎管短缩距离均显著短于骨对骨融合组(P<0.05)。

核心结论

  • 在严重脊柱侧凸患者中,凸侧脊柱的短缩距离不能代表中央椎管的短缩距离。
  • 在适当选择的骨对骨融合患者中,脊柱短缩手术是可行选择,中央椎管短缩距离显著短于凸侧脊柱短缩距离。

研究设计与样本

  • 回顾性研究,纳入2013年7月至2015年6月在本机构连续收治的52例接受三柱脊柱截骨术的严重僵硬性脊柱侧凸患者。
  • 术前脊髓功能分型为A型31例、B型10例、C型11例。
  • 截骨类型为扩大椎弓根截骨9例、后路全椎体切除43例。
  • 术中采用多模式神经电生理监测。

主要发现

  • 三维模型测得的脊柱短缩距离(27.8 mm)在统计学上短于术中测量值(32.8 mm)(P<0.05),但两者强相关(r=0.82)。
  • 中央椎管短缩距离显著短于凸侧脊柱短缩距离(P<0.05)。
  • 前柱支撑植骨组的凸侧脊柱短缩距离和中央椎管短缩距离均显著短于骨对骨融合组(P<0.05)。

关键数值与推荐

  • 三维模型脊柱短缩距离27.8 mm vs 术中测量脊柱短缩距离32.8 mm(P<0.05),相关系数r=0.82。

局限性

  • 证据等级为4级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Retrospective study. OBJECTIVES: This study is to measure and analyze the changes of three-dimensional (3D) distances of spinal column and spinal canal at the three-column osteotomy sites and address their clinical and neurologic significance. SUMMARY OF BACKGROUND DATA: Three-column osteotomies were developed to treat severe and stiff spine deformities with insufficient understanding on the safe limit of spine shortening and the relationship between the shortening distance of the spinal column and that of the spinal canal. METHODS: Records of 52 continuous patients with severe and stiff scoliosis treated with three-column spine osteotomies at our institution from July 2013 to June 2015 were reviewed. The preoperative spinal cord function classification were type A in 31 cases, type B in 10 cases, and type C in 11 cases. The types of osteotomies carried out were extended pedicle subtraction osteotomy in nine patients and posterior vertebral column resection in 43 patients. Multimodality neuromonitoring strategies were adopted intraoperatively. 3D pre- and postoperative spine models were reconstructed from the computed tomography (CT) scans. The distances of convex and concave spinal column and the spinal canal shortening were measured and analyzed. RESULTS: The spinal column shortening distance (SCSD) measured on the 3D models (27.8 mm) were statistically shorter than those measured intraoperatively (32.8 mm) (P < 0.05); however, they were strongly correlated statistically (r = 0.82). The central spinal canal shortening distance (CCSD) was significantly shorter than the convex SCSD (P < 0.05). The convex SCSD and CCSD were significantly shorter in cases with anterior column strut graft than in those with bone-on-bone fusion (P < 0.05). CONCLUSION: The shortening distance of the convex spinal column cannot represent that of the central spinal canal in patients with severe scoliosis. The spinal column shortening procedure in appropriately selected patient groups with bone-on-bone fusion is a viable option with the CCSD being significantly shorter than the convex SCSD. LEVEL OF EVIDENCE: 4.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。