在南欧通过常规CT对骨质疏松症进行机会性筛查
本研究以双能X线吸收测定法(DXA)为参考,评估在肿瘤患者因其他临床指征行腹部CT时利用骨密度(BMD)早期检出骨质疏松症的可行性,并对外部验证160 HU阈值。共纳入326名连续成人,结果显示腹部CT图像无需额外辐射或费用即可识别骨质疏松BMD患者,未校准的L1 CT衰减阈值160 HU灵敏度超过90%。
要点
- 腹部CT图像可识别骨质疏松BMD患者,无需额外辐射暴露或费用。
- 未校准L1 CT衰减阈值160 HU区分骨质疏松BMD的灵敏度超过90%。
- 在肿瘤患者中,未校准L1值比DXA能检出更多伴有脊柱压缩性骨折的骨质疏松患者。
核心结论
- 因其他原因获得的腹部CT图像无需额外辐射暴露或费用即可识别骨质疏松BMD患者。
- 在肿瘤患者中,未校准的L1值比DXA能检出更多伴有脊柱压缩性骨折的骨质疏松患者。
研究设计与样本
- 队列包含326名连续成人在6个月期间因任何指征进行的CT-DXA配对,年龄62.4 ± 12.38岁(均值 ± 标准差)。
- 在L1、L2、L3和L4椎体轴位横断面测量骨小梁的CT衰减值(HU),并通过矢状面重建视图评估椎体压缩性骨折。
- 计算诊断性能指标和诊断骨质疏松的受试者工作特征曲线下面积(AUC)。
- 以DXA为参考,比较校准与未校准测量,并对提出的160 HU高灵敏度阈值进行外部验证。
主要发现
- 对于DXA定义的骨质疏松患者,L1至L4任一椎体水平的BMD值均统计学显著降低(p < 0.001)。
- 校准与未校准BMD值显著相关(R² = 0.833,p < 0.01)。
- 未校准L1 CT衰减阈值160 HU区分骨质疏松BMD的灵敏度超过90%,阈值73 HU的特异度超过90%。
- 59%的椎体压缩性骨折患者DXA T值显示非骨质疏松。
关键数值与推荐
- 未校准L1 CT衰减阈值160 HU区分骨质疏松BMD的灵敏度超过90%。
- 未校准L1 CT衰减阈值73 HU区分骨质疏松BMD的特异度超过90%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Feasibility evaluation of early detection of osteoporosis in oncologic patients by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed for other clinical indications, by using dual-energy X-ray absorptiometry (DXA) as reference. Abdominal CT images can identify patients with osteoporosis BMD without additional radiation exposure or cost. INTRODUCTION: The purpose of the study is to evaluate the feasibility of early detection of osteoporosis by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed in oncologic patients, comparing calibrated and uncalibrated measurements by using dual-energy X-ray absorptiometry (DXA) as reference. We also performed an external validation of a threshold of 160 Hounsfield units (HU), proposed as highly sensitive. METHODS: Cohort comprised CT-DXA pairs within a 6-month period performed for any indication on 326 consecutive adults, aged 62.4 ± 12.38 years (mean ± standard deviation). CT attenuation of trabecular bone in HU was measured at the axial cross sections of L1, L2, L3, and L4 vertebrae. Vertebral compression fractures were assessed by sagittal reconstruction view. Diagnostic performance measures and the area under the receiver operator characteristic curve (AUC) for diagnosing osteoporosis were calculated. RESULTS: BMD values were statistical significantly lower at any vertebral level from L1 to L4 for patients with osteoporosis defined by DXA (p < 0.001). Calibrated and uncalibrated BMD values were significantly correlated (R 2 = 0.833, p < 0.01). An uncalibrated L1 CT attenuation threshold of 160 HU was more than 90 % sensitive, and a threshold of 73 HU was more than 90 % specific for distinguishing osteoporosis BMD. Fifty-nine percent of patients with vertebral compression fracture had non-osteoporotic DXA T-scores. CONCLUSIONS: Abdominal CT images obtained for other reasons can identify patients with osteoporosis BMD without additional radiation exposure or cost. Uncalibrated values at L1 can detect more osteoporosis patients with spinal compression fractures than DXA in oncologic patients.
引用
- Alacreu E, Moratal D, Arana E, et al. Opportunistic screening for osteoporosis by routine CT in Southern Europe. Osteoporos Int. 2017. PMID: 28108802. doi:10.1007/s00198-016-3804-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。